An Approach for Investigating Thermal and Structural Responses of Stay Cables Subjected to Sheath Fires
Buildings · 19.08.2026 · 16 (16) · 3303
DOI: 10.3390/buildings16163303 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 19.08.2026. Verfasst von Feng Xu und 7 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
This paper presents a methodology to evaluate the entire process of thermal evolution and fracture failure within stay cables subjected to sheath fires. Computer software FDS 2021 and ABAQUS 2021 are applied to build a sequentially thermos–mechanics coupled method integrating thermal, structural, and fracture dynamic analyses in stay cables under sheath fire exposure conditions. Herein, three representative fire scenarios including full-circumferential, top-side, and bottom-side ignition are reconstructed. Further, 127 individual wires, accounting for interstitial cavity radiation and contact heat transfer, are utilized to perform analysis on sectional temperature in stay cables. The results indicate that the ignition mode dictates the cross-sectional temperature gradient, with localized ignitions inducing highly asymmetric thermal fields and pronounced internal bending moments. Elevated temperatures trigger a progressive load redistribution from the degraded fire-facing wires to cooler internal layers. Ultimately, abrupt global fracture occurs when the residual ultimate load-carrying capacity intersects with the actual applied tension, resulting in a fracture morphology that closely corresponds to the spatial thermal distribution. Furthermore, the structural capacity degradation exhibits three distinct time-dependent stages: a slow degradation stage, a sharp decline stage, and a recovery stage. Among the analyzed scenarios, full-circumferential ignition induces the most drastic overall capacity reduction, while bottom-side ignition poses a markedly greater rupture risk than top-side ignition.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Xu, F., Lu, Z., Liu, C., Zhou, E., Chen, Z., Xin, X., Ding, Y., & Wang, S. (2026). An Approach for Investigating Thermal and Structural Responses of Stay Cables Subjected to Sheath Fires. Buildings, 16(16), 3303. https://doi.org/10.3390/buildings16163303
Vancouver
Xu F, Lu Z, Liu C, Zhou E, Chen Z, Xin X, et al. An Approach for Investigating Thermal and Structural Responses of Stay Cables Subjected to Sheath Fires. Buildings. 2026;16(16):3303. doi:10.3390/buildings16163303
BibTeX
@article{Xu2026,
author = {Xu, Feng and Lu, Zelei and Liu, Chang and Zhou, Enhai and Chen, Zhaohui and Xin, Xiong and Ding, Yuhang and Wang, Shichao},
title = {An Approach for Investigating Thermal and Structural Responses of Stay Cables Subjected to Sheath Fires},
journal = {Buildings},
year = {2026},
volume = {16},
number = {16},
pages = {3303},
doi = {10.3390/buildings16163303}
}