Heat Transfer Performance and On–Off Thermal Response of a Building Wall Embedded with a Reversible Loop Heat Pipe
Buildings · 09.08.2026 · 16 (16) · 3165
DOI: 10.3390/buildings16163165 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 09.08.2026. Verfasst von Junxiang Chen und 3 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Building on a previously developed valve-controlled reversible loop heat pipe (RLHP) and the corresponding RLHP-embedded wall, component- and wall-scale experiments were conducted. The heat-transfer performance of the RLHP was evaluated at filling ratios of 10–70% and heating powers of 25–400 W, and its forward and reverse operation was evaluated at the component scale using a filling ratio of 50%. The on–off dynamic responses of the RLHP-embedded wall and a reference wall were subsequently compared under heating powers of 20–200 W. The results showed that filling ratios ranging from 40% to 70% provided a relatively effective operating range under the tested conditions. Among the tested filling ratios, 50% exhibited the lowest and most stable apparent equivalent thermal resistance, with an average value of approximately 0.039 m2·K/W. At 400 W, the quasi-steady average temperature differences during forward and reverse operation were 17.2 °C and 16.9 °C, respectively. At 200 W, the first-hour temperature rise on the unheated side was approximately 6 °C for the RLHP-embedded wall, compared with 1.2 °C for the reference wall. During the combined heating-off–valve-closed stage, the heat-retention duration increased with the preceding heating power.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Chen, J., Li, Y., Wu, H., & Yang, L. (2026). Heat Transfer Performance and On–Off Thermal Response of a Building Wall Embedded with a Reversible Loop Heat Pipe. Buildings, 16(16), 3165. https://doi.org/10.3390/buildings16163165
Vancouver
Chen J, Li Y, Wu H, Yang L. Heat Transfer Performance and On–Off Thermal Response of a Building Wall Embedded with a Reversible Loop Heat Pipe. Buildings. 2026;16(16):3165. doi:10.3390/buildings16163165
BibTeX
@article{Chen2026,
author = {Chen, Junxiang and Li, Yonghan and Wu, Huijun and Yang, Lixiu},
title = {Heat Transfer Performance and On–Off Thermal Response of a Building Wall Embedded with a Reversible Loop Heat Pipe},
journal = {Buildings},
year = {2026},
volume = {16},
number = {16},
pages = {3165},
doi = {10.3390/buildings16163165}
}
EUVIMED