EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Finite Element Analysis of Seismic Performance of Post-Cast UHPC Beam–Column Assembled Joints

Feng Gao, Yue Li, Guosheng Zhang, Mintao Ding, Shijun Ding, Tiantian Chen, Jia Sun, Hui Lin

Buildings · 09.08.2026 · 16 (16) · 3159

DOI: 10.3390/buildings16163159 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 09.08.2026. Verfasst von Feng Gao und 7 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: science and technology project of the headquarters of State Grid Corporation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Prefabricated post-pouring UHPC (ultra-high performance concrete) beam–column joints have the advantages of strong integrity, excellent seismic performance and good durability, but there are also problems of easy cracking of old and new concrete interfaces and concrete near the interface. Therefore, a new type of post-cast UHPC joint is designed in this paper. The joint is connected by post-cast UHPC at the beam and column sections far from the core area, and the keyway is set in the connection section to solve the defect that the old and new interfaces easily crack. The refined finite element model of the joint was established by using the finite element software ABAQUS (2023). Through the simulation of 10 working conditions, the typical failure modes and seismic performance of the joint were discussed in depth, and the influence of key parameters such as the lap length of steel bars, the strength of steel bars and the strength of post-pouring UHPC was analyzed. The results show that the joint cracks first appear at the junction of the beam–column core area and develop along the cut-off interface between ordinary concrete and UHPC. No macroscopic cracks were observed in the post-pouring UHPC connection section, and the structure was finally destroyed due to the crushing of ordinary concrete. Increasing the lap length of the steel bar can improve the peak bearing capacity and stiffness of the joint, but it will accelerate the stiffness degradation. Increasing the strength grade of steel bars can significantly improve the bearing capacity and stiffness of the joints, but the energy dissipation capacity is slightly reduced. In addition, the improvement effect of UHPC strength is closely related to the strength of steel bars: when an HRB500 steel bar is used, high-strength UHPC can show better bearing capacity, stiffness and energy dissipation performance, while the improvement effect is not significant when an HRB400 steel bar is used. The research results can effectively inhibit the development of interface cracks and provide a theoretical reference for the subsequent full-scale test and the seismic design of precast joints with post-cast UHPC connections.

Förderung

  • science and technology project of the headquarters of State Grid Corporation of China

Zitieren

APA

Gao, F., Li, Y., Zhang, G., Ding, M., Ding, S., Chen, T., Sun, J., & Lin, H. (2026). Finite Element Analysis of Seismic Performance of Post-Cast UHPC Beam–Column Assembled Joints. Buildings, 16(16), 3159. https://doi.org/10.3390/buildings16163159

Vancouver

Gao F, Li Y, Zhang G, Ding M, Ding S, Chen T, et al. Finite Element Analysis of Seismic Performance of Post-Cast UHPC Beam–Column Assembled Joints. Buildings. 2026;16(16):3159. doi:10.3390/buildings16163159

BibTeX
@article{Gao2026,
  author = {Gao, Feng and Li, Yue and Zhang, Guosheng and Ding, Mintao and Ding, Shijun and Chen, Tiantian and Sun, Jia and Lin, Hui},
  title = {Finite Element Analysis of Seismic Performance of Post-Cast UHPC Beam–Column Assembled Joints},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {16},
  pages = {3159},
  doi = {10.3390/buildings16163159}
}
Kostenlos starten →