Fachartikel in der Zeitschrift Buildings, online erschienen am 05.08.2026. Verfasst von Abdelhakim Mesloub und 5 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific Research Deanship at University of Ha’il Saudi Arabia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Narrow internal lightwells are often featured in multi-story residential buildings in hot arid climates in order to daylight rooms where direct façade access is not possible, but privacy-driven window closure strongly limits the daylighting potential of these shafts. This paper examines whether three retrofit daylighting strategies—(1) increased shaft wall reflectance, (2) multi-level tubular daylighting devices (MTDDs), and (3) inclined lightwell remodeling with clerestory openings—can retrofit a common residential lightwell in Ha’il City, Saudi Arabia for high performance, high-efficiency daylighting performance under typical privacy-constrained urban conditions. A calibrated daylight model was developed using field measurements of the existing lightwell conditions, and the three retrofit strategies were then evaluated through Radiance-based simulations. The calibrated Radiance model showed good agreement with observations (MBE = −9.6%, RMSE = 17%). It was found that the aged lightwell received less than 0.5% of outdoor daylight in clear summer conditions and that the performance was highly seasonal and orientation-dependent, with 15–20% higher summer peaks in one monitored room, while both rooms remained largely below 100 lx in winter and overcast periods. Simulations determined that the base case results in the ground and first-floor areas remaining comparatively lowly illuminated (UDI

Förderung

  • Scientific Research Deanship at University of Ha’il Saudi Arabia

Zitieren

APA

Mesloub, A., Alshenaifi, M., Aldersoni, A., Alghaseb, M., Hafnaoui, R., & Doulos, L. T. (2026). Transforming Residential Lightwells into High-Performance Daylighting Systems Through Optical and Geometric Retrofit Optimization. Buildings, 16(15), 3104. https://doi.org/10.3390/buildings16153104

Vancouver

Mesloub A, Alshenaifi M, Aldersoni A, Alghaseb M, Hafnaoui R, Doulos LT. Transforming Residential Lightwells into High-Performance Daylighting Systems Through Optical and Geometric Retrofit Optimization. Buildings. 2026;16(15):3104. doi:10.3390/buildings16153104

BibTeX
@article{Mesloub2026,
  author = {Mesloub, Abdelhakim and Alshenaifi, Mohammad and Aldersoni, Ali and Alghaseb, Mohammad and Hafnaoui, Rim and Doulos, Lambros T.},
  title = {Transforming Residential Lightwells into High-Performance Daylighting Systems Through Optical and Geometric Retrofit Optimization},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {15},
  pages = {3104},
  doi = {10.3390/buildings16153104}
}
Kostenlos starten →