Experimental Investigation of the Mechanical and Electrical Properties of Cement Mortar Incorporating Fly Ash and Lead Zirconate Titanate
Buildings · 29.07.2026 · 16 (15) · 3019
DOI: 10.3390/buildings16153019 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 29.07.2026. Verfasst von Shu-Chuan Chang und 3 weiteren Autor:innen. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study experimentally investigated the mechanical properties and electrical resistivity of cement mortar incorporating fly ash and lead zirconate titanate (PZT) for potential application in smart and disaster-resilient building materials. Class F fly ash replaced cement at 0%, 10%, 20%, and 30% by volume. In the PZT mixtures, 5% of the fine-aggregate volume was replaced with PZT powder. Flowability, compressive strength, ultrasonic pulse velocity, water absorption, and electrical resistivity were evaluated at curing ages of 1, 7, 28, and 56 days. Electrical resistivity was measured under saturated surface-dry (SSD) and oven-dried (OD) conditions using direct-current voltages of 50 and 100 V, corresponding to nominal electric-field intensities of 10 and 20 V/cm. At 28 days, compressive strength ranged from 31.0 to 20.4 MPa for the control mixtures and from 29.0 to 19.0 MPa for the PZT mixtures as the fly ash content increased. Under the 50 V SSD condition, the corresponding resistivity ranges were 1870–1588 and 1419–1286 Ω·cm, respectively, whereas under the 100 V OD condition, they were 2671–3013 and 3247–3415 Ω·cm. Increasing the fly ash content improved flowability but generally reduced compressive strength and ultrasonic pulse velocity and increased water absorption because the low-calcium Class F fly ash slowed strength development. The PZT mixtures exhibited slightly lower compressive strength, likely owing to weaker interfacial bonding, but showed distinct electrical behaviour: PZT reduced resistivity under SSD conditions and increased it under OD conditions relative to the control mixtures. Resistivity increased with compressive strength under SSD conditions but decreased with compressive strength under OD conditions because pore water enhanced ionic conduction. Higher applied voltage also reduced the measured resistivity. Overall, moisture condition and measurement voltage strongly governed the electrical response, while the incorporation of 5 vol.% PZT altered the electrical-resistivity characteristics while producing only relatively small differences in the measured basic engineering properties.
Zitieren
APA
Chang, S., Lin, K., Hsu, C., & Wang, H. (2026). Experimental Investigation of the Mechanical and Electrical Properties of Cement Mortar Incorporating Fly Ash and Lead Zirconate Titanate. Buildings, 16(15), 3019. https://doi.org/10.3390/buildings16153019
Vancouver
Chang S, Lin K, Hsu C, Wang H. Experimental Investigation of the Mechanical and Electrical Properties of Cement Mortar Incorporating Fly Ash and Lead Zirconate Titanate. Buildings. 2026;16(15):3019. doi:10.3390/buildings16153019
BibTeX
@article{Chang2026,
author = {Chang, Shu-Chuan and Lin, Keng-Ta and Hsu, Chao-Ching and Wang, Her-Yung},
title = {Experimental Investigation of the Mechanical and Electrical Properties of Cement Mortar Incorporating Fly Ash and Lead Zirconate Titanate},
journal = {Buildings},
year = {2026},
volume = {16},
number = {15},
pages = {3019},
doi = {10.3390/buildings16153019}
}