Research on Mechanical Behavior of Doubler Plate-Reinforced CHS-to-SHS T-Joints Under Brace Axial Compression
Buildings · 21.07.2026 · 16 (14) · 2901
DOI: 10.3390/buildings16142901 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 21.07.2026. Verfasst von Huan-Yan Zeng und 5 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nation Natural Science Foundation of China, Natural Science Foundation of Hunan Province of China, Hunan Provincial Department of Education.
Abstract (Originalsprache)
To address the engineering issues of local plastic buckling of the chord wall and low ultimate capacity in unreinforced T-joints with square chord and circular brace (CHS-to-SHS) under brace axial compression, this paper proposes a doubler plate-reinforced CHS-to-SHS T-joint configuration. The mechanical behavior of the-reinforced joints is investigated based on a refined finite element (FE) model calibrated against experimental data. An extensive parametric analysis is conducted using FE method to investigate the key factors influencing the failure mode, ultimate capacity, and reinforcement efficiency of doubler plate-reinforced CHS-to-SHS T-joints, including the non-dimensional geometric parameters of the doubler plate (α2, β2, τ2), and the ratio between the brace diameter and chord width (β). The results indicate that the doubler plate thickness has the most significant effect on capacity enhancement, while the width has a limited influence. The ultimate capacity exhibits an initial increase followed by a plateau with increasing doubler plate length, with the optimal length ratio α2 equal to 1.2. A decreasing trend in the strength ratio is observed with an increase in β. The highest strength ratio of 3.29 is obtained at β = 0.445, and this value declines markedly to 1.4 when β increases to 0.795. However, β ≤ 0.445 tends to induce brace axial yielding, whereas β ≥ 0.795 is prone to cause chord bending failure—both cases constituting over-strengthening. Based on the systematic parametric results, a capacity calculation formula for doubler plate-reinforced CHS-to-SHS T-joints is established and demonstrated to show good agreement with the FE results, providing theoretical basis and design recommendations for the engineering design of doubler plate-reinforced CHS-to-SHS T-joints.
Förderung
- Nation Natural Science Foundation of China
- Natural Science Foundation of Hunan Province of China
- Hunan Provincial Department of Education
- Education Department of Hunan Province
- Guiding Plan Project of Hengyang Municipality
- Education Department of Zhejiang Province
- Hunan Institute of Technology
Zitieren
APA
Zeng, H., Yuan, Z., Zhao, Y., Yao, Y., Liao, H., & Guo, P. (2026). Research on Mechanical Behavior of Doubler Plate-Reinforced CHS-to-SHS T-Joints Under Brace Axial Compression. Buildings, 16(14), 2901. https://doi.org/10.3390/buildings16142901
Vancouver
Zeng H, Yuan Z, Zhao Y, Yao Y, Liao H, Guo P. Research on Mechanical Behavior of Doubler Plate-Reinforced CHS-to-SHS T-Joints Under Brace Axial Compression. Buildings. 2026;16(14):2901. doi:10.3390/buildings16142901
BibTeX
@article{Zeng2026,
author = {Zeng, Huan-Yan and Yuan, Zhi-Shen and Zhao, Yang-Zhi and Yao, Yao and Liao, Hai-Jun and Guo, Peng-Cheng},
title = {Research on Mechanical Behavior of Doubler Plate-Reinforced CHS-to-SHS T-Joints Under Brace Axial Compression},
journal = {Buildings},
year = {2026},
volume = {16},
number = {14},
pages = {2901},
doi = {10.3390/buildings16142901}
}