EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cooking Fume Particulate Matter as an Indoor Air Pollution Source: Comparative Measurement Methods and Correction Factors

Pan Wang, Linghui Kong, Muhammad Azher Hassan, Fei Wang, Jinyu He, Xin Wang

Buildings · 14.07.2026 · 16 (14) · 2793

DOI: 10.3390/buildings16142793 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 14.07.2026. Verfasst von Pan Wang und 5 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cooking fumes are an important source of indoor and outdoor air pollution. Containing potentially carcinogenic particles and toxic chemical components, they pose significant health threats, making precise detection essential for risk prevention and the formulation of emission standards. This study used the manual gravimetric analysis as the benchmark reference method to systematically evaluate the performance of three alternative measurement techniques: (1) an optical particle counter (Promo 3000, Palas GmbH, Karlsruhe, Germany), (2) a photometer (DustTrak 8533, TSI, Shoreview, MN, USA), and (3) infrared spectrophotometry. A data correction model was constructed by simulating typical cooking conditions. Results indicate that the manual gravimetric analysis yielded the highest particulate concentrations. Infrared spectrophotometry measured only 75.6% of the benchmark value, mainly because of its selectivity toward oil-derived organic components and possible sampling losses. The optical particle counter, influenced by particle light-scattering properties and density differences, underestimated the mass concentration of particles larger than 0.3 μm, capturing only 46.9% of the benchmark value. Conversely, the photometer exhibited the smallest deviation, with readings closest to the gravimetric reference under the tested cooking fumes conditions. Theoretical derivation and data fitting determined correction factors of 1.32 for infrared spectrophotometry, 2.13 for the optical particle counter for particles larger than 0.3 μm, and 0.97 for the photometer. This correction system enables the standardization of data across different detection methods, allowing on-site monitoring data to be calibrated against the gravimetric reference method.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Wang, P., Kong, L., Hassan, M. A., Wang, F., He, J., & Wang, X. (2026). Cooking Fume Particulate Matter as an Indoor Air Pollution Source: Comparative Measurement Methods and Correction Factors. Buildings, 16(14), 2793. https://doi.org/10.3390/buildings16142793

Vancouver

Wang P, Kong L, Hassan MA, Wang F, He J, Wang X. Cooking Fume Particulate Matter as an Indoor Air Pollution Source: Comparative Measurement Methods and Correction Factors. Buildings. 2026;16(14):2793. doi:10.3390/buildings16142793

BibTeX
@article{Wang2026,
  author = {Wang, Pan and Kong, Linghui and Hassan, Muhammad Azher and Wang, Fei and He, Jinyu and Wang, Xin},
  title = {Cooking Fume Particulate Matter as an Indoor Air Pollution Source: Comparative Measurement Methods and Correction Factors},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {14},
  pages = {2793},
  doi = {10.3390/buildings16142793}
}
Kostenlos starten →