EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Torsion–Bending–Shear-Coupled Failure of SRC Staggered-Floor Beam–Column Joints Under a Quasi-Static Middle-Column Removal Scenario

Fangfang Zhang, Qiang Pei, Neng Quan, Yingzhu Zhong, Bo Wang, Hailin Kang

Buildings · 08.07.2026 · 16 (14) · 2719

DOI: 10.3390/buildings16142719 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 08.07.2026. Verfasst von Fangfang Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Dalian University, National Natural Science Foundation of China, Key Laboratory for Prediction & Control on Complicated Structure System of the Education Department of Liaoning Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Staggered-floor steel-reinforced concrete beam–column joints are extensively applied in turbine buildings of nuclear power plants to meet the requirements of spatial layout and pipeline arrangement. Such joints feature distinct geometric discontinuity and suffer additional torsion effects as well as asymmetric stress distribution when the middle column is lost, which greatly impairs the structural progressive collapse resistance. In this study, three 1/5-scale joint specimens, consisting of two staggered-floor steel-reinforced concrete joints and one reinforced concrete joint, were tested under vertical monotonic static loading. The failure pattern, deformation property, torsional performance, strain development and load-bearing mechanism were comprehensively analyzed. Finite element models considering the coupling effect of torsion, bending and shear were established and validated via ABAQUS. The test results show that the peak load-bearing capacities of the SRC-1, SRC-2, and RC specimens were 148.2 kN, 149.7 kN, and 69.3 kN, respectively. Compared with the RC specimen, the peak load-bearing capacity of the SRC specimens more than doubled, indicating that the embedded H-section steel can significantly improve the load-bearing capacity of staggered beam–column joints. However, when the staggered height distance was increased from 140 mm to 280 mm, the ultimate collapse displacement of the specimens decreased from 340 mm to 310 mm, indicating a reduction in deformation capacity. The finite element model reasonably reproduced the specimens’ primary load–displacement response and damage characteristics, with a peak load error of 8.93% for SRC-1. Finally, corresponding design recommendations are put forward for staggered-floor steel-reinforced concrete joints in nuclear power plant structures.

Förderung

  • Dalian University
  • National Natural Science Foundation of China
  • Key Laboratory for Prediction & Control on Complicated Structure System of the Education Department of Liaoning Province

Zitieren

APA

Zhang, F., Pei, Q., Quan, N., Zhong, Y., Wang, B., & Kang, H. (2026). Torsion–Bending–Shear-Coupled Failure of SRC Staggered-Floor Beam–Column Joints Under a Quasi-Static Middle-Column Removal Scenario. Buildings, 16(14), 2719. https://doi.org/10.3390/buildings16142719

Vancouver

Zhang F, Pei Q, Quan N, Zhong Y, Wang B, Kang H. Torsion–Bending–Shear-Coupled Failure of SRC Staggered-Floor Beam–Column Joints Under a Quasi-Static Middle-Column Removal Scenario. Buildings. 2026;16(14):2719. doi:10.3390/buildings16142719

BibTeX
@article{Zhang2026,
  author = {Zhang, Fangfang and Pei, Qiang and Quan, Neng and Zhong, Yingzhu and Wang, Bo and Kang, Hailin},
  title = {Torsion–Bending–Shear-Coupled Failure of SRC Staggered-Floor Beam–Column Joints Under a Quasi-Static Middle-Column Removal Scenario},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {14},
  pages = {2719},
  doi = {10.3390/buildings16142719}
}
Kostenlos starten →