Experimental Study on the Seismic Performance of Assembled Shear Walls Based on UHPC Connections
Buildings · 02.07.2026 · 16 (13) · 2644
DOI: 10.3390/buildings16132644 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 02.07.2026. Verfasst von Gang Chen und 5 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Scientific Research Program Project of Shanghai Municipal Science and Technology Commission.
Abstract (Originalsprache)
This paper investigates the seismic performance of precast concrete shear-wall subassemblies connected by post-cast ultra-high performance concrete (UHPC) zones and short lap-spliced reinforcement with a lap length of 10d, where d denotes the diameter of the reinforcement bar. Seven quasi-static cyclic tests were conducted, including one cast-in-place control specimen, five specimens with horizontal UHPC back-cast joints at the wall base, and one exploratory specimen with both horizontal and vertical UHPC back-cast joints. The variables considered were the joint arrangement and the axial compression ratio. The specimens with horizontal joints generally exhibited compression-flexure-dominated damage, and the crushing zone shifted from the wall-footing interface to the ordinary concrete immediately above the UHPC back-cast zone. The specimen with the vertical joint (TW6) exhibited bending-shear damage, accompanied by limited in-plane lateral slip at the beam–wall joint and shear damage of several vertical bars. Specimen TW2, with an axial compression ratio of 0.30, was identified as a construction-quality-sensitive case because an insufficient local UHPC cover caused splitting damage and reduced hysteretic stability. The strain measurements indicate that, within the limits of the present instrumentation, the 10d lap in the UHPC zone provided effective stress transfer in the tested specimens; however, direct interface-slip and bond-slip tests are still required for generalized design verification. Under an axial compression ratio of 0.20, TW1 and TW6 showed comparable seismic indices to the cast-in-place specimen, but the conclusions are limited to the tested configurations. All specimens reached ultimate drift ratios greater than 1/100, and their seismic performance is discussed together with failure mode, stiffness degradation, energy dissipation, and connection reliability.
Förderung
- National Natural Science Foundation of China
- Scientific Research Program Project of Shanghai Municipal Science and Technology Commission
Zitieren
APA
Chen, G., Yuan, S., Zheng, Q., Long, L., Li, H., & Nong, D. (2026). Experimental Study on the Seismic Performance of Assembled Shear Walls Based on UHPC Connections. Buildings, 16(13), 2644. https://doi.org/10.3390/buildings16132644
Vancouver
Chen G, Yuan S, Zheng Q, Long L, Li H, Nong D. Experimental Study on the Seismic Performance of Assembled Shear Walls Based on UHPC Connections. Buildings. 2026;16(13):2644. doi:10.3390/buildings16132644
BibTeX
@article{Chen2026,
author = {Chen, Gang and Yuan, Shiwei and Zheng, Qizhen and Long, Libo and Li, Huiyan and Nong, Decai},
title = {Experimental Study on the Seismic Performance of Assembled Shear Walls Based on UHPC Connections},
journal = {Buildings},
year = {2026},
volume = {16},
number = {13},
pages = {2644},
doi = {10.3390/buildings16132644}
}
EUVIMED