Heat Loss Analysis and Energy-Saving Optimization of a High-Power Electric Air Heater
Buildings · 29.06.2026 · 16 (13) · 2595
DOI: 10.3390/buildings16132595 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 29.06.2026. Verfasst von Huajie Cheng und 9 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Basic Research Program of Jiangsu.
Abstract (Originalsprache)
High-power electric air heaters are key charging components in air thermal energy storage systems, but the dominant heat-loss regions and retrofit basis of existing devices remain unclear. In this study, a three-dimensional conjugate heat-transfer model was developed for an existing 1200 kW vertical electric air heater and validated using three steady-state experimental cases, with a maximum outlet-temperature deviation of 2.17%. Based on the validated model, temperature-field characteristics and segmental heat-loss distributions were analyzed under different mass flow rates. The results show that heat loss was highly non-uniform: Segments 2 and 3 accounted for 37.26% and 54.51% of the total heat loss, respectively, contributing 91.77% in total. A targeted local retrofit scheme was, therefore, proposed by filling the non-flowing inner-cylinder region in Segments 2 and 3 with glass wool and enhancing insulation near local cooling boundaries. After optimization, the average total heat loss decreased from 31.94 kW to 17.69 kW, corresponding to a 44.6% reduction. Under the rated condition, the outlet temperature increased from 1421.6 K to 1482.0 K, providing 584.8 kWh of additional effective thermal storage per cycle and an estimated payback period of 399 d. This study provides a diagnosis-guided retrofit approach for existing high-power electric air heaters.
Förderung
- National Natural Science Foundation of China
- Basic Research Program of Jiangsu
Zitieren
APA
Cheng, H., Xu, C., Wu, H., Cheng, Y., Hou, J., Zhang, G., Zhou, J., Ma, M., Zhang, J., & Dai, Z. (2026). Heat Loss Analysis and Energy-Saving Optimization of a High-Power Electric Air Heater. Buildings, 16(13), 2595. https://doi.org/10.3390/buildings16132595
Vancouver
Cheng H, Xu C, Wu H, Cheng Y, Hou J, Zhang G, et al. Heat Loss Analysis and Energy-Saving Optimization of a High-Power Electric Air Heater. Buildings. 2026;16(13):2595. doi:10.3390/buildings16132595
BibTeX
@article{Cheng2026,
author = {Cheng, Huajie and Xu, Chenghui and Wu, Han and Cheng, Yuehua and Hou, Junlin and Zhang, Guangwei and Zhou, Jialin and Ma, Mingyu and Zhang, Jingyang and Dai, Zhaofeng},
title = {Heat Loss Analysis and Energy-Saving Optimization of a High-Power Electric Air Heater},
journal = {Buildings},
year = {2026},
volume = {16},
number = {13},
pages = {2595},
doi = {10.3390/buildings16132595}
}