Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 28.06.2026. Verfasst von Xu Li und 3 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shandong Provincial Natural Science Foundation, National Natural Science Foundation of China, Beijing Polytechnic University Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As the foundational sensing element for AI-driven structural health monitoring systems, piezoelectric ceramic (PZT) is widely adopted in civil engineering to capture high-fidelity physical responses. Distinct from existing studies focusing on the actuation mode or static/quasi-static sensing conditions, this study specifically investigates the dynamic strain transfer behavior of surface-bonded PZT sensors in sensing mode by establishing a three-layer analytical model incorporating the adhesive shear lag effect, validated by finite element simulations. Accordingly, a dual-regime dynamic calibration strategy is proposed: employing a single sensitivity value for low-frequency global structural vibrations and frequency-dependent correction for high-frequency elastic wave applications. Parametric analyses on PZT thickness, adhesive thickness, and shear modulus quantitatively demonstrate that reducing PZT/adhesive thicknesses and increasing adhesive shear modulus extend the compensation-negligible frequency range (defined by a 10% strain ratio deviation threshold) and elevate the first-order longitudinal natural frequency; practical sensor fabrication guidelines are further derived from these findings. Additionally, the system’s first-order longitudinal natural frequency stabilizes when the host-to-PZT area ratio (As/Ap) exceeds a critical threshold. These findings provide a theoretical basis for the optimal design, dynamic calibration, and engineering application of bonded PZT sensors.

Förderung

  • Shandong Provincial Natural Science Foundation
  • National Natural Science Foundation of China
  • Beijing Polytechnic University Foundation

Zitieren

APA

Li, X., Wang, W., Min, W., & Wang, D. (2026). Dynamic Strain Transfer Behavior of Bonded PZT Sensors for Civil Engineering Structural Health Monitoring. Buildings, 16(13), 2585. https://doi.org/10.3390/buildings16132585

Vancouver

Li X, Wang W, Min W, Wang D. Dynamic Strain Transfer Behavior of Bonded PZT Sensors for Civil Engineering Structural Health Monitoring. Buildings. 2026;16(13):2585. doi:10.3390/buildings16132585

BibTeX
@article{Li2026,
  author = {Li, Xu and Wang, Wenming and Min, Weixue and Wang, Dongdong},
  title = {Dynamic Strain Transfer Behavior of Bonded PZT Sensors for Civil Engineering Structural Health Monitoring},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {13},
  pages = {2585},
  doi = {10.3390/buildings16132585}
}
Kostenlos starten →