Internal Force Analysis, Deformation Behavior, and Failure Modes of Double-Row Pile Foundations for Bridges on Sloping Ground
Buildings · 22.06.2026 · 16 (12) · 2466
DOI: 10.3390/buildings16122466 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 22.06.2026. Verfasst von Hongying Zhang und 4 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
With the construction of transportation networks in mountainous areas under the Western Development Strategy, double-row pile foundations on slopes have been widely applied. However, due to the distortion of the soil stress field, their load distribution mechanism under bidirectional loading is extremely complex. To investigate the internal force distribution laws and deformation and failure modes, a systematic study was conducted utilizing theoretical derivation: 60 scale indoor physical model tests, and 3D refined finite element numerical simulations. The results show that the force distribution of double-row piles in slope environments differs significantly: the upper-row piles, affected by active earth pressure and sliding thrust, bear significantly higher load than the lower-row piles; meanwhile, the lower-row piles, constrained by stronger deep soil, can more fully utilize their vertical bearing capacity. Parametric analysis indicates that the terrain slope has a nonlinear amplification effect on the displacement difference at the pile top, with 50° being the critical mutation slope that triggers the failure of connection joints. In addition, the deformation mode of double-row piles undergoes a change when the pile spacing exceeds 5 times the pile diameter. Therefore, in practical engineering design, the traditional concept of symmetrical reinforcement should be abandoned in favor of differentiated bending reinforcement targeting the shallow surface layer of the upper-row piles and the deep inflection point of the lower-row piles. For working conditions with a slope greater than 50°, additional measures such as prestressed anchor cables must be applied to reduce the sliding load. Meanwhile, the row spacing should be strictly controlled within 5 times the pile diameter to fully ensure the diaphragm effect and the overall synergistic stability of the structure.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Zhang, H., Liu, H., Yuan, H., Wang, Z., & Chen, M. (2026). Internal Force Analysis, Deformation Behavior, and Failure Modes of Double-Row Pile Foundations for Bridges on Sloping Ground. Buildings, 16(12), 2466. https://doi.org/10.3390/buildings16122466
Vancouver
Zhang H, Liu H, Yuan H, Wang Z, Chen M. Internal Force Analysis, Deformation Behavior, and Failure Modes of Double-Row Pile Foundations for Bridges on Sloping Ground. Buildings. 2026;16(12):2466. doi:10.3390/buildings16122466
BibTeX
@article{Zhang2026,
author = {Zhang, Hongying and Liu, Haisheng and Yuan, Huazhi and Wang, Zhengzhen and Chen, Mingjie},
title = {Internal Force Analysis, Deformation Behavior, and Failure Modes of Double-Row Pile Foundations for Bridges on Sloping Ground},
journal = {Buildings},
year = {2026},
volume = {16},
number = {12},
pages = {2466},
doi = {10.3390/buildings16122466}
}
EUVIMED