Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 14.06.2026. Verfasst von Merve Arpacıktaş und 2 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Erciyes University Scientific Research Projects Coordination Unit.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study experimentally investigated the structural behavior of reinforced concrete beams with circular openings created by core drilling in the midspan and shear span regions under fixed-ended boundary conditions. A total of 21 full-scale beams with shear span-to-effective depth ratios (a/d) of 1.25, 1.75, and 2.25 were tested under a four-point bending setup. After concrete hardening, 100, 200, and 300 mm diameter openings were introduced by core drilling. The results showed that the effect of opening location on load-carrying capacity varied with the a/d ratio. In the a/d = 1.25 and 1.75 series, openings in the shear span caused more pronounced reductions, whereas in the a/d = 2.25 series, midspan openings became more influential. Increasing the opening diameter reduced both load-carrying capacity and energy dissipation capacity, and this reduction varied with opening location and a/d ratio. Openings in the shear span led to shear failure in the a/d = 1.25 and 1.75 series, whereas flexural effects became more pronounced in the a/d = 2.25 series. Nevertheless, 300 mm openings caused shear failure even in beams expected to exhibit more flexure-dominated behavior.

Förderung

  • Erciyes University Scientific Research Projects Coordination Unit

Zitieren

APA

Arpacıktaş, M., Altun, F., & Sülev, E. (2026). Experimental Investigation of Fixed-Ended RC Beams with Circular Post-Installed Openings Across Different a/d Ratios. Buildings, 16(12), 2375. https://doi.org/10.3390/buildings16122375

Vancouver

Arpacıktaş M, Altun F, Sülev E. Experimental Investigation of Fixed-Ended RC Beams with Circular Post-Installed Openings Across Different a/d Ratios. Buildings. 2026;16(12):2375. doi:10.3390/buildings16122375

BibTeX
@article{Arpackta2026,
  author = {Arpacıktaş, Merve and Altun, Fatih and Sülev, Ertan},
  title = {Experimental Investigation of Fixed-Ended RC Beams with Circular Post-Installed Openings Across Different a/d Ratios},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {12},
  pages = {2375},
  doi = {10.3390/buildings16122375}
}
Kostenlos starten →