Static Performance of UT-Type Semi-Rigid Joints Considering Loss of Bolt Pretension
Buildings · 02.06.2026 · 16 (11) · 2245
DOI: 10.3390/buildings16112245 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 02.06.2026. Verfasst von Menghan Sun und 5 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Heilongjiang Province.
Abstract (Originalsprache)
To investigate the static behavior of UT-type assembled semi-rigid joints and the effects of bolt pretension loss, two representative joint configurations, UT250 × 150 and UT400 × 200, were studied by combining full-scale tests with refined finite element analysis using ABAQUS. Pure bending, bending-shear, and constant-axial-force-coupled loading conditions were considered, with particular attention paid to the effects of single-bolt and multiple-bolt pretension loss on moment capacity, initial rotational stiffness (Ky), interface slip, and the failure mode of the joints. The results show that the UT-type joint mainly fails through concentrated plastic yielding in the joint zone, and its ultimate moment (Mu) is 12.3–18.7% higher than that of a conventional bolted-welded joint, satisfying the design principle of “strong joint and weak member”. Loss of pretension in a single bolt has only a limited influence on the yield moment (My) and ultimate moment (Mu), with a maximum reduction of 8.0% in the ultimate moment (Mu) under negative pure bending; however, it causes clear degradation in the initial rotational stiffness (Ky), and pretension loss in the upper bolt produces a greater stiffness reduction than loss in a single lower bolt, with a maximum reduction of 33.43%. Multiple-bolt pretension loss exhibits a pronounced coupling effect. Simultaneous loss in lower bolts on the same side is the most unfavorable case, leading to a maximum stiffness reduction of 67.78% (coupling coefficient of 1.17), whereas diagonal loss is relatively controllable and generally keeps the stiffness reduction within 7%. When the axial compression ratio does not exceed 0.3, the mechanical response of the joint remains relatively stable, and the adverse effect of pretension loss can be alleviated to a certain extent; further increases in the axial compression ratio accelerate the degradation of both stiffness and load-carrying capacity. The present study provides a useful reference for the design optimization, construction quality control, and in-service maintenance of UT-type semi-rigid joints.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Heilongjiang Province
Zitieren
APA
Sun, M., He, L., Chen, Y., Yang, M., Jiang, X., & Yang, Z. (2026). Static Performance of UT-Type Semi-Rigid Joints Considering Loss of Bolt Pretension. Buildings, 16(11), 2245. https://doi.org/10.3390/buildings16112245
Vancouver
Sun M, He L, Chen Y, Yang M, Jiang X, Yang Z. Static Performance of UT-Type Semi-Rigid Joints Considering Loss of Bolt Pretension. Buildings. 2026;16(11):2245. doi:10.3390/buildings16112245
BibTeX
@article{Sun2026,
author = {Sun, Menghan and He, Luyao and Chen, Yutao and Yang, Miaomiao and Jiang, Xin and Yang, Zailin},
title = {Static Performance of UT-Type Semi-Rigid Joints Considering Loss of Bolt Pretension},
journal = {Buildings},
year = {2026},
volume = {16},
number = {11},
pages = {2245},
doi = {10.3390/buildings16112245}
}