EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Twin Shield Tunnelling on Pile Foundations of Existing Airport Buildings in Cohesive Soil Strata

Qingjun Xian, Feixiang Yu, Shun Xiao, Huiqiang Liu, Xianmei Wang, Haitao Dou, Yuanxiao Xiao, Jing Cui, Bin Zhang

Buildings · 28.05.2026 · 16 (11) · 2161

DOI: 10.3390/buildings16112161 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 28.05.2026. Verfasst von Qingjun Xian und 8 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Henan, Natural Science Foundation of China, Fundamental Research Funds for the Henan Provincial Colleges and Universities in Henan University of Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Based on the Zhengzhou–Xuchang Intercity Railway tunnel project passing beneath Terminal 1 of Xinzheng International Airport, this study employs a three-dimensional numerical analysis model to investigate the effects of tunnel depth and pile foundation structure on ground surface settlement and pile foundation response during twin-line shield tunnelling in typical cohesive soils under tunnel side-crossing and under-crossing conditions. The results indicate that during tunnel side-crossing, the ground surface settlement profiles evolved from V-shaped to W-shaped before and after twin-tunnel breakthrough. With increasing tunnel depth, the lateral displacement profiles of the left-row and right-row piles transformed from spindle-shaped to X-shaped. With increasing pile count, the maximum axial force per pile decreased from 320.1 kN in the single-pile configuration to 197.4 kN in the six-pile configuration, a reduction of 38.3%. During tunnel under-crossing, the lateral displacement profiles of both left-row and right-row piles exhibit X-shaped profiles at different tunnel depths, and the pile-top displacement varies slightly with a maximum of 1.1 mm. With increasing pile count, the maximum axial force per pile decreased from 202.2 kN to 132.1 kN, a reduction of 34.7%. The findings provide valuable reference for design and construction control of twin-line shield tunnels crossing existing airport pile foundations in cohesive soil.

Förderung

  • Natural Science Foundation of Henan
  • Natural Science Foundation of China
  • Fundamental Research Funds for the Henan Provincial Colleges and Universities in Henan University of Technology

Zitieren

APA

Xian, Q., Yu, F., Xiao, S., Liu, H., Wang, X., Dou, H., Xiao, Y., Cui, J., & Zhang, B. (2026). Influence of Twin Shield Tunnelling on Pile Foundations of Existing Airport Buildings in Cohesive Soil Strata. Buildings, 16(11), 2161. https://doi.org/10.3390/buildings16112161

Vancouver

Xian Q, Yu F, Xiao S, Liu H, Wang X, Dou H, et al. Influence of Twin Shield Tunnelling on Pile Foundations of Existing Airport Buildings in Cohesive Soil Strata. Buildings. 2026;16(11):2161. doi:10.3390/buildings16112161

BibTeX
@article{Xian2026,
  author = {Xian, Qingjun and Yu, Feixiang and Xiao, Shun and Liu, Huiqiang and Wang, Xianmei and Dou, Haitao and Xiao, Yuanxiao and Cui, Jing and Zhang, Bin},
  title = {Influence of Twin Shield Tunnelling on Pile Foundations of Existing Airport Buildings in Cohesive Soil Strata},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {2161},
  doi = {10.3390/buildings16112161}
}