Residual Mechanical Properties of Printable Concrete Subjected to Elevated Temperatures

Kai Xiong, Junyi Zhao, Yao Rong, Youhua Zhang, Zewen Zhu, Chengke Zhang, Huijie Zou, Yong Yuan

Buildings · 26.05.2026 · 16 (11) · 2125

DOI: 10.3390/buildings16112125 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 26.05.2026. Verfasst von Kai Xiong und 7 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Commission of Shanghai Municipality, Department of Transportation of Jiangxi Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The construction industry is under increasing pressure to reduce its carbon footprint, driving the development of low-carbon construction technologies. Printable concrete has attracted increasing attention in the construction sector due to its advantages in automation and material efficiency, which are considered beneficial for sustainable and low-carbon construction practices. However, its structural performance under fire exposure remains insufficiently understood, particularly regarding the anisotropic mechanical response induced by layer-by-layer fabrication. This study experimentally investigates the mechanical behavior of printable concrete at ambient temperature and after exposure to elevated temperatures of 200 °C, 400 °C, and 600 °C. Manually printed specimens were prepared to replicate the layered characteristics of printable concrete, while cast concrete specimens served as a reference. Results show clear anisotropy in compressive strength among the X, Y, and Z loading directions, with the Z-direction exhibiting the highest strength due to improved interlayer integrity. Compared with cast concrete, printable concrete showed up to 37.77% lower compressive strength at ambient temperature. After thermal exposure, the compressive strength of printable concrete decreased by 16.68%, 34.40%, and 37.54% after exposure to 200 °C, 400 °C, and 600 °C, respectively, while the elastic modulus decreased by up to 78.18%. Mass loss and surface cracking intensified with increasing temperature, reflecting progressive dehydration and microstructural deterioration. These findings provide important insights into the fire performance and post-fire structural assessment of printable concrete.

Förderung

  • Science and Technology Commission of Shanghai Municipality
  • Department of Transportation of Jiangxi Province

Zitieren

APA

Xiong, K., Zhao, J., Rong, Y., Zhang, Y., Zhu, Z., Zhang, C., Zou, H., & Yuan, Y. (2026). Residual Mechanical Properties of Printable Concrete Subjected to Elevated Temperatures. Buildings, 16(11), 2125. https://doi.org/10.3390/buildings16112125

Vancouver

Xiong K, Zhao J, Rong Y, Zhang Y, Zhu Z, Zhang C, et al. Residual Mechanical Properties of Printable Concrete Subjected to Elevated Temperatures. Buildings. 2026;16(11):2125. doi:10.3390/buildings16112125

BibTeX
@article{Xiong2026,
  author = {Xiong, Kai and Zhao, Junyi and Rong, Yao and Zhang, Youhua and Zhu, Zewen and Zhang, Chengke and Zou, Huijie and Yuan, Yong},
  title = {Residual Mechanical Properties of Printable Concrete Subjected to Elevated Temperatures},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {2125},
  doi = {10.3390/buildings16112125}
}
Kostenlos starten →