EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Temperature and Humidity Distribution and Ventilation Optimization in an Existing Underground Utility Tunnel Under Different Ventilation Modes

Xingyou Li, Songying Huang, Qichang Zeng, Minfeng Zheng, Weikang Wu, Peifeng Shi, Bingren Shen, Xi Liu

Buildings · 21.05.2026 · 16 (10) · 2035

DOI: 10.3390/buildings16102035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 21.05.2026. Verfasst von Xingyou Li und 7 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In hot and humid regions, urban underground utility tunnels are susceptible to high temperature and humidity due to moist inlet air, cable heat dissipation, and limited ventilation jointly affecting the internal environment. To address this issue, an alternating ventilation strategy, in which fan operation is periodically reversed to switch between air supply and exhaust, is proposed. Compared to conventional mechanical ventilation, this strategy overcomes the constraints of unidirectional airflow and mitigates thermal and humidity stratification, with low retrofit requirements and good adaptability. Ventilation performance was evaluated using non-guarantee rates for temperature and relative humidity, i.e., the ratio of the number of measurement points where the temperature/relative humidity exceeds 40 °C/65% to the total number of measurement points in the utility tunnel (TNGR and RHNGR), non-uniformity coefficients (KT and KRH), and mean temperature (Tm). The alternating mode outperformed the conventional mode, reducing TNGR by 6.0% and Tm by 0.3 °C while improving temperature and humidity distributions and lowering cable temperatures. Although the reduction in Tm appears modest, it is practically meaningful because it helps weaken thermal stratification and local overheating, improves cable operating conditions, and may reduce the need for high-airflow operation when tunnel temperatures approach the permissible limit. Response surface methodology was further used to optimize the alternating ventilation parameters, indicating that the recommended fan commutation frequency is 2 under different inlet air temperatures. CFD validation confirmed the effectiveness of the optimized scheme. At an inlet air temperature of 35 °C, KRH decreased from 11.9% to 11.0% and Tm decreased from 37.5 °C to 36.9 °C.

Zitieren

APA

Li, X., Huang, S., Zeng, Q., Zheng, M., Wu, W., Shi, P., Shen, B., & Liu, X. (2026). Temperature and Humidity Distribution and Ventilation Optimization in an Existing Underground Utility Tunnel Under Different Ventilation Modes. Buildings, 16(10), 2035. https://doi.org/10.3390/buildings16102035

Vancouver

Li X, Huang S, Zeng Q, Zheng M, Wu W, Shi P, et al. Temperature and Humidity Distribution and Ventilation Optimization in an Existing Underground Utility Tunnel Under Different Ventilation Modes. Buildings. 2026;16(10):2035. doi:10.3390/buildings16102035

BibTeX
@article{Li2026,
  author = {Li, Xingyou and Huang, Songying and Zeng, Qichang and Zheng, Minfeng and Wu, Weikang and Shi, Peifeng and Shen, Bingren and Liu, Xi},
  title = {Temperature and Humidity Distribution and Ventilation Optimization in an Existing Underground Utility Tunnel Under Different Ventilation Modes},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {10},
  pages = {2035},
  doi = {10.3390/buildings16102035}
}
Kostenlos starten →