EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Behavior of Precast Beams with Emulative Connections Using Grouted Sleeves and Mechanical Couplers Under Cyclic Loading

Viorel Popa, Mihai Pavel, Eugen Lozincă, Andrei Papurcu

Buildings · 19.05.2026 · 16 (10) · 2001

DOI: 10.3390/buildings16102001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 19.05.2026. Verfasst von Viorel Popa und 3 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The construction of single-story industrial halls in high-seismicity regions requires reliable beam-to-column connections to ensure adequate structural stiffness and strength. This paper investigates the emulative performance of a rigid precast beam–column connection utilizing threaded couplers and grouted corrugated steel sleeves. An experimental pro-gram was conducted on five scaled specimens—one monolithic reference and four pre-cast—subjected to quasi-static cyclic loading. The objective was to verify if the precast system achieved emulative behavior. Experimental results confirm this goal was fully achieved: the precast specimen exhibited a maximum recorded force nearly identical to the value recorded for the monolithic reference. Furthermore, the total dissipated energy for the precast joint had only a marginal 2.6% difference from the monolithic reference. Results demonstrate that the proposed solution provides emulative behavior consistent with monolithic casting. Specifically, the specimens achieved plastic deformation capacities exceeding 3%, surpassing current seismic design code requirements. While smaller diameter rebars (D14) experienced tensile failure at approximately 3% to 4% drift due to strain localization, specimen with larger D25 bars reached 4% drift without major damage. This paper concludes that the connection is suitable for seismic applications provided large diameter rebars (≥20 mm) are used.

Zitieren

APA

Popa, V., Pavel, M., Lozincă, E., & Papurcu, A. (2026). Behavior of Precast Beams with Emulative Connections Using Grouted Sleeves and Mechanical Couplers Under Cyclic Loading. Buildings, 16(10), 2001. https://doi.org/10.3390/buildings16102001

Vancouver

Popa V, Pavel M, Lozincă E, Papurcu A. Behavior of Precast Beams with Emulative Connections Using Grouted Sleeves and Mechanical Couplers Under Cyclic Loading. Buildings. 2026;16(10):2001. doi:10.3390/buildings16102001

BibTeX
@article{Popa2026,
  author = {Popa, Viorel and Pavel, Mihai and Lozincă, Eugen and Papurcu, Andrei},
  title = {Behavior of Precast Beams with Emulative Connections Using Grouted Sleeves and Mechanical Couplers Under Cyclic Loading},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {10},
  pages = {2001},
  doi = {10.3390/buildings16102001}
}
Kostenlos starten →