A Physics-Constrained Surrogate Model for Multi-Hazard Collapse Assessment of Buildings Under Post-Fire Concurrent Wind-Earthquake Loading
Buildings · 12.05.2026 · 16 (10) · 1921
DOI: 10.3390/buildings16101921 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 12.05.2026. Verfasst von Ahmed Elgammal und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 113 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Scholarship Council, University of Birmingham.
Abstract (Originalsprache)
Conventional structural design frameworks assess natural hazards as statistically independent phenomena, a practice that can lead to significant underestimation of risk for structures subjected to sequential or concurrent hazards. The generation of probabilistic fragility functions under such cascading loads, particularly for post-fire seismic events, presents a computational barrier for standard non-linear dynamic analysis. To address this barrier, this study introduces a comprehensive computational framework centered on a physics-constrained neural network (PCNN) to serve as a high-fidelity surrogate model. The framework first uses a non-linear 12-degree-of-freedom structural model to generate a baseline dataset of collapse times under post-fire, concurrent wind-earthquake loading via the computationally efficient endurance time (ET) method, confirming that wind effects are negligible under ambient conditions and that the framework correctly identifies this hazard hierarchy without prior labeling, while fire and seismic parameters dominate. This dataset is subsequently used to train the PCNN, which is validated to achieve exceptional predictive accuracy (R2= 0.991), performing on par with a state-of-the-art Random Forest model while enforcing physical constraints. A feature importance analysis confirmed that structural collapse is dominated by fire intensity (≈55%) and initial structural period (≈45%). The validated PCNN is then applied to demonstrate the framework’s capability, rapidly generating fragility curves that quantify the catastrophic effect of fire on seismic resilience. This analysis reveals that a severe 800 °C localized fire reduces the structure’s median collapse capacity by 94.7%, thereby establishing the proposed framework as a successful template for tackling complex, non-linear problems in multi-hazard engineering.
Förderung
- China Scholarship Council
- University of Birmingham
Zitieren
APA
Elgammal, A., Ali, Y., Shirkhani, A., & Martinez-Vazquez, P. (2026). A Physics-Constrained Surrogate Model for Multi-Hazard Collapse Assessment of Buildings Under Post-Fire Concurrent Wind-Earthquake Loading. Buildings, 16(10), 1921. https://doi.org/10.3390/buildings16101921
Vancouver
Elgammal A, Ali Y, Shirkhani A, Martinez-Vazquez P. A Physics-Constrained Surrogate Model for Multi-Hazard Collapse Assessment of Buildings Under Post-Fire Concurrent Wind-Earthquake Loading. Buildings. 2026;16(10):1921. doi:10.3390/buildings16101921
BibTeX
@article{Elgammal2026,
author = {Elgammal, Ahmed and Ali, Yasmin and Shirkhani, Amir and Martinez-Vazquez, Pedro},
title = {A Physics-Constrained Surrogate Model for Multi-Hazard Collapse Assessment of Buildings Under Post-Fire Concurrent Wind-Earthquake Loading},
journal = {Buildings},
year = {2026},
volume = {16},
number = {10},
pages = {1921},
doi = {10.3390/buildings16101921}
}
EUVIMED