EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Seismic Response and Mitigation Measures of Large Unequal-Span Subway Station Structures in Liquefiable Sites

Jing Yang, Jianning Wang, Zigang Xu, Chen Wang, Ruimeng Xia

Buildings · 29.03.2026 · 16 (7) · 1359

DOI: 10.3390/buildings16071359 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 29.03.2026. Verfasst von Jing Yang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of Yangzhou, National Natural Science Foundation of China, General Program for Basic Research (Natural Science) of Jiangsu Provincial Department of Education.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The deformation of surrounding soil primarily governs the behavior of underground structures. Consequently, variations in their external geometry significantly affect their overall seismic response. Moreover, large soil deformations and structural uplift caused by liquefaction severely threaten their seismic safety. While most previous studies have focused on conventional rectangular subway stations, the seismic performance of novel varying-span structures remains largely unexplored. In this study, nonlinear dynamic time-history analyses are conducted to investigate the soil–structure interaction (SSI) of large unequal-span subway stations in liquefiable sites. Furthermore, the seismic responses of both the structure and the surrounding soil are systematically evaluated under various burial depths of the liquefiable layer. Finally, a U-shaped foundation reinforcement method is proposed to mitigate structural uplift. The results show that unequal-span structures suppress liquefaction in lateral soil, whereas significant liquefaction occurs beneath the base slab and cantilevered middle slabs. The burial depth of the liquefiable layer has a negligible effect on the liquefaction state directly under the center span. Regarding structural response, global uplift follows a spatial pattern that peaks at the center span and gradually attenuates laterally. Although the proposed U-shaped reinforcement effectively reduces both total and differential uplift, it does not fundamentally change the underlying liquefaction mechanism. Specifically, reinforcing the soil under cantilevered sections minimizes differential uplift while enhancing the overall economic efficiency of the seismic design. These findings provide a scientific basis for optimizing the seismic resilience of complex underground structures, contributing to the development of resource-efficient and disaster-resilient urban underground infrastructure in liquefaction-prone regions.

Förderung

  • National Natural Science Foundation of Yangzhou
  • National Natural Science Foundation of China
  • General Program for Basic Research (Natural Science) of Jiangsu Provincial Department of Education
  • Young Elite Scientists Sponsorship Program

Zitieren

APA

Yang, J., Wang, J., Xu, Z., Wang, C., & Xia, R. (2026). Seismic Response and Mitigation Measures of Large Unequal-Span Subway Station Structures in Liquefiable Sites. Buildings, 16(7), 1359. https://doi.org/10.3390/buildings16071359

Vancouver

Yang J, Wang J, Xu Z, Wang C, Xia R. Seismic Response and Mitigation Measures of Large Unequal-Span Subway Station Structures in Liquefiable Sites. Buildings. 2026;16(7):1359. doi:10.3390/buildings16071359

BibTeX
@article{Yang2026,
  author = {Yang, Jing and Wang, Jianning and Xu, Zigang and Wang, Chen and Xia, Ruimeng},
  title = {Seismic Response and Mitigation Measures of Large Unequal-Span Subway Station Structures in Liquefiable Sites},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {7},
  pages = {1359},
  doi = {10.3390/buildings16071359}
}
Kostenlos starten →