EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Real-Time Damage Detection and Electromechanical Response of Steel Fiber-Reinforced Self-Sensing Concrete Under Compressive and Tensile Loading

Ahmed S. Eisa, Ahmad A. Attia, Jozef Selín, Pavol Purcz

Buildings · 24.03.2026 · 16 (7) · 1283

DOI: 10.3390/buildings16071283 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 24.03.2026. Verfasst von Ahmed S. Eisa und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The integration of real-time monitoring capabilities into concrete materials offers significant potential for improving the safety and durability of building infrastructure. This study investigates the real-time electromechanical behavior of steel fiber-reinforced self-sensing concrete under compressive and splitting tensile loading. Eighteen cubes (150 × 150 × 150 mm) and eighteen cylinders (150 × 300 mm) containing 0.5%, 1.5%, and 3% steel fiber volume fractions were tested. Electrical resistance was continuously recorded at one-second intervals using an Arduino–ESP32-based system, enabling in situ tracking of damage evolution. The conductive steel fiber network functioned as an intrinsic sensing phase, where load-induced microstructural changes altered electrical pathways. Resistance variations consistently preceded visible cracking, with pronounced nonlinear increases observed at 65–80% of peak load, indicating micro-crack initiation. Distinct electromechanical stages were identified, including elastic stability, compaction-induced resistance reduction near yield, and rapid resistance growth during crack propagation. Higher fiber contents improved both mechanical performance and sensing sensitivity through enhanced crack-bridging and conductive network stability. Although curing age influenced baseline resistance, reliable real-time damage detection was achieved across all specimens. The findings demonstrate the feasibility of steel fiber-reinforced concrete as a cost-effective, distributed monitoring material for early damage detection in building structures.

Zitieren

APA

Eisa, A. S., Attia, A. A., Selín, J., & Purcz, P. (2026). Real-Time Damage Detection and Electromechanical Response of Steel Fiber-Reinforced Self-Sensing Concrete Under Compressive and Tensile Loading. Buildings, 16(7), 1283. https://doi.org/10.3390/buildings16071283

Vancouver

Eisa AS, Attia AA, Selín J, Purcz P. Real-Time Damage Detection and Electromechanical Response of Steel Fiber-Reinforced Self-Sensing Concrete Under Compressive and Tensile Loading. Buildings. 2026;16(7):1283. doi:10.3390/buildings16071283

BibTeX
@article{Eisa2026,
  author = {Eisa, Ahmed S. and Attia, Ahmad A. and Selín, Jozef and Purcz, Pavol},
  title = {Real-Time Damage Detection and Electromechanical Response of Steel Fiber-Reinforced Self-Sensing Concrete Under Compressive and Tensile Loading},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {7},
  pages = {1283},
  doi = {10.3390/buildings16071283}
}