Performance Evaluation of ENVI-Met in Simulating Microclimates Beneath Elevated Buildings in Cold Climates
Buildings · 19.03.2026 · 16 (6) · 1215
DOI: 10.3390/buildings16061215 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 19.03.2026. Verfasst von Xuan Ma und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Beilin District Science and Technology Project, Shaanxi Provincial Science and Technology Plan Project.
Abstract (Originalsprache)
Sustainable development in cities has gained popularity due to the emergence of numerous urban challenges in harsh environments. Selecting an accurate turbulence model in CFD is crucial for assessing the outdoor environment. Among the widely used microclimate simulation tools, ENVI-met stands out for its convenience and its proven effectiveness in urban microclimate studies. Elevated design, often referred to as ‘lifted up design,’ is standard in architectural practice, serving both as recreational spaces and corridors, potentially improving thermal comfort. To ensure reliable microclimate modeling, assessments in such areas should be validated against empirical data. This study compares the microclimatic conditions in open space beneath an elevated building using ENVI-met with on-site meteorological data collected in Xi’an, China, across three days with varying weather conditions. The results show that ENVI-met can reasonably reproduce air temperature (R2 = 0.80–0.96, RMSE = 0.67–1.42 °C), relative humidity (R2 = 0.85–0.99, RMSE = 2.83–9.32%), and mean radiant temperature (R2 = 0.87–0.90, RMSE = 4.11–7.23 °C) under different conditions, though some deviations exist—especially with diffuse radiation, which ENVI-met tends to underestimate beneath elevated structures. Despite these discrepancies, the model performance was evaluated by comparing field measurements with ENVI-met outputs, and the results indicate that ENVI-met can provide useful insights for simulating microclimate conditions in open spaces beneath elevated buildings under different weather conditions.
Förderung
- National Natural Science Foundation of China
- Beilin District Science and Technology Project
- Shaanxi Provincial Science and Technology Plan Project
- Weiyang District Science and Technology Plan
Zitieren
APA
Ma, X., Yang, Y., & Li, T. (2026). Performance Evaluation of ENVI-Met in Simulating Microclimates Beneath Elevated Buildings in Cold Climates. Buildings, 16(6), 1215. https://doi.org/10.3390/buildings16061215
Vancouver
Ma X, Yang Y, Li T. Performance Evaluation of ENVI-Met in Simulating Microclimates Beneath Elevated Buildings in Cold Climates. Buildings. 2026;16(6):1215. doi:10.3390/buildings16061215
BibTeX
@article{Ma2026,
author = {Ma, Xuan and Yang, Yuhuan and Li, Tongxin},
title = {Performance Evaluation of ENVI-Met in Simulating Microclimates Beneath Elevated Buildings in Cold Climates},
journal = {Buildings},
year = {2026},
volume = {16},
number = {6},
pages = {1215},
doi = {10.3390/buildings16061215}
}
EUVIMED