EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

2D and 3D Stability Analysis of Rectangular Tunnel Roof Based on Tensile Cut-Off Criterion

Wenqian Cai, De Zhou, Chaoqun Hou, Yongxin Li, Long Xia, Guihua Long

Buildings · 12.03.2026 · 16 (6) · 1132

DOI: 10.3390/buildings16061132 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 12.03.2026. Verfasst von Wenqian Cai und 5 weiteren Autor:innen. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: project “Key technologies for deformation control in shield tunneling through operated subway station and utility tunnels” of Shenzhen Municipal Group Co., Ltd., project “Key technologies for TBM safe tunneling under unfavorable geological conditions” of Shenzhen Municipal Group Co., Ltd..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tunnel roof is subjected to a complex tension-shear stress state after excavation. A tensile cut-off strength criterion is introduced in this study and combined with the upper bound limit analysis method to investigate the stability of a rectangular tunnel roof. First, the expression for the internal energy dissipation rate is derived for the circular cut-off segment of the failure criterion. Power functionals Φ are established for both two-dimensional and three-dimensional rotational collapse mechanisms. The analytical equations for the failure surface are obtained using the variational method. The strength reduction method that incorporates the cut-off criterion is proposed to quantify roof stability. The investigation into the morphology of the collapsing block indicates that the supporting pressure and the reduction coefficient ξ have a significant influence on the collapse shape of the tunnel, suggesting that attention should be paid to the suspension effect of the tunnel roof on stability. The range of the collapsing block under three-dimensional conditions is found to be larger than that under two-dimensional conditions. Parametric influences on the safety factor are examined. Finally, dimensionless design charts for the critical reinforcement pressure are provided for practical tunnel support design.

Förderung

  • project “Key technologies for deformation control in shield tunneling through operated subway station and utility tunnels” of Shenzhen Municipal Group Co., Ltd.
  • project “Key technologies for TBM safe tunneling under unfavorable geological conditions” of Shenzhen Municipal Group Co., Ltd.

Zitieren

APA

Cai, W., Zhou, D., Hou, C., Li, Y., Xia, L., & Long, G. (2026). 2D and 3D Stability Analysis of Rectangular Tunnel Roof Based on Tensile Cut-Off Criterion. Buildings, 16(6), 1132. https://doi.org/10.3390/buildings16061132

Vancouver

Cai W, Zhou D, Hou C, Li Y, Xia L, Long G. 2D and 3D Stability Analysis of Rectangular Tunnel Roof Based on Tensile Cut-Off Criterion. Buildings. 2026;16(6):1132. doi:10.3390/buildings16061132

BibTeX
@article{Cai2026,
  author = {Cai, Wenqian and Zhou, De and Hou, Chaoqun and Li, Yongxin and Xia, Long and Long, Guihua},
  title = {2D and 3D Stability Analysis of Rectangular Tunnel Roof Based on Tensile Cut-Off Criterion},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {6},
  pages = {1132},
  doi = {10.3390/buildings16061132}
}
Kostenlos starten →