Mechanical Performance Analysis of a Fluid Viscous Inerter Damper and Evaluation of Its Control Effect on Structural Responses

Tianlong Wang, Shixuan Yang, Xiangyu Shi, Xun’an Zhang, Zhaohui Cai

Buildings · 09.03.2026 · 16 (5) · 1083

DOI: 10.3390/buildings16051083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 09.03.2026. Verfasst von Tianlong Wang und 4 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Research and Development Project of China State Construction Engineering Corporation, Ltd., Science and Technology Research and Development Project of China Construction Sixth Engineering Bureau Corp., Ltd., National Key Research and Development Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of high-efficiency energy dissipation devices is crucial for mitigating the significant threat posed by seismic loads to modern buildings. Therefore, the purpose of this work is to design a novel fluid viscous inerter damper (FVID) and systematically investigate its mechanical performance through theoretical derivations, experiments, and finite element simulations. Furthermore, the impact of FVIDs on the seismic performance of structures is comprehensively evaluated. The advantage of FVID is that under external excitation, the fluid can flow through multiple channels, thereby generating inertial and damping forces to dissipate energy. The theoretical model of FVID’s output force is determined based on FVID’s construction and fluid flow characteristics. The hysteresis performance of the FVID is evaluated through cyclic loading tests, and the influence of the cross-sectional radius and number of turns of the helical tube on its output force is analyzed. By performing finite element simulations of the internal flow field of FVID, the distributions of fluid pressure and velocity at different positions within FVID are analyzed. Based on Simulink, the focus is on investigating the control effect of FVID on structural responses under non-pulse near-field ground motions, pulse-type near-field ground motions, and far-field ground motions. The results indicate that the FVID has a strong energy-dissipation capacity and can effectively reduce structural responses under different types of earthquakes. The cross-sectional radius of the helical tube is a key design parameter that determines the damper’s output force. For highly destructive pulse-type near-field ground motions, FVIDs still exhibit excellent comprehensive performance in the structure.

Förderung

  • Science and Technology Research and Development Project of China State Construction Engineering Corporation, Ltd.
  • Science and Technology Research and Development Project of China Construction Sixth Engineering Bureau Corp., Ltd.
  • National Key Research and Development Program of China

Zitieren

APA

Wang, T., Yang, S., Shi, X., Zhang, X., & Cai, Z. (2026). Mechanical Performance Analysis of a Fluid Viscous Inerter Damper and Evaluation of Its Control Effect on Structural Responses. Buildings, 16(5), 1083. https://doi.org/10.3390/buildings16051083

Vancouver

Wang T, Yang S, Shi X, Zhang X, Cai Z. Mechanical Performance Analysis of a Fluid Viscous Inerter Damper and Evaluation of Its Control Effect on Structural Responses. Buildings. 2026;16(5):1083. doi:10.3390/buildings16051083

BibTeX
@article{Wang2026,
  author = {Wang, Tianlong and Yang, Shixuan and Shi, Xiangyu and Zhang, Xun’an and Cai, Zhaohui},
  title = {Mechanical Performance Analysis of a Fluid Viscous Inerter Damper and Evaluation of Its Control Effect on Structural Responses},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {5},
  pages = {1083},
  doi = {10.3390/buildings16051083}
}