EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Thermal Performance Optimization of Trombe Walls: A Comprehensive Experimental Study in Cold Regions

Shimeng Wang, Jianing Wang, Yan Tian, Huiju Guo, Yi Zhai, Qun Zhou, Hiroatsu Fukuda, Yafei Wang

Buildings · 08.03.2026 · 16 (5) · 1073

DOI: 10.3390/buildings16051073 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 08.03.2026. Verfasst von Shimeng Wang und 7 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Development Plan Project of Jilin Province, China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In cold regions with prolonged subzero temperatures and abundant solar radiation, Trombe walls serve as high-efficiency passive solar building envelopes for improving indoor thermal comfort. This study aims to optimize the thermal performance of Trombe walls via a multimodal data analysis framework and a multiview measurement algorithm. Three distinct Trombe wall configurations were constructed and continuously monitored for 60 consecutive days under typical winter conditions (average temperature: −15 °C; solar radiation intensity: 800–1100 W/m2). Field-measured datasets, including solar radiation intensity, hourly air temperature distribution, and heat exchange efficiency, were systematically analyzed to quantify the impacts of ventilation mode, air gap width, and insulation thickness on thermal performance. The results demonstrate that the hourly peak surface temperature of the optimized Trombe wall reaches 25.7 °C at 13:00, which significantly improves indoor thermal comfort compared with conventional buildings. An air gap width of 6 cm minimizes indoor temperature fluctuations (fluctuation coefficient = 0.08), while a 20 mm insulation layer stabilizes heat loss reduction at 31.1% relative to non-insulated walls. The optimal operational parameter combination (6 cm air gap, 16 °C indoor set temperature) was determined based on the lowest temperature fluctuation and highest thermal efficiency, with experimental results deviating by less than 5% from established analytical models. This study verifies the reliability of the multimodal data analysis framework for Trombe wall performance evaluation, providing practical design guidelines for passive solar building envelopes in cold regions.

Förderung

  • Science and Technology Development Plan Project of Jilin Province, China

Zitieren

APA

Wang, S., Wang, J., Tian, Y., Guo, H., Zhai, Y., Zhou, Q., Fukuda, H., & Wang, Y. (2026). Thermal Performance Optimization of Trombe Walls: A Comprehensive Experimental Study in Cold Regions. Buildings, 16(5), 1073. https://doi.org/10.3390/buildings16051073

Vancouver

Wang S, Wang J, Tian Y, Guo H, Zhai Y, Zhou Q, et al. Thermal Performance Optimization of Trombe Walls: A Comprehensive Experimental Study in Cold Regions. Buildings. 2026;16(5):1073. doi:10.3390/buildings16051073

BibTeX
@article{Wang2026,
  author = {Wang, Shimeng and Wang, Jianing and Tian, Yan and Guo, Huiju and Zhai, Yi and Zhou, Qun and Fukuda, Hiroatsu and Wang, Yafei},
  title = {Thermal Performance Optimization of Trombe Walls: A Comprehensive Experimental Study in Cold Regions},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {5},
  pages = {1073},
  doi = {10.3390/buildings16051073}
}
Kostenlos starten →