EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Failure of a Code-Compliant Reinforced Concrete Building: Damage Patterns and Nonlinear Seismic Response

Onur Onat, İbrahim Baran Karaşin, Burak Yön, Sadık Varolgüneş, Mehmet Emin Öncü, Ali Uslu

Buildings · 04.03.2026 · 16 (5) · 1012

DOI: 10.3390/buildings16051012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 04.03.2026. Verfasst von Onur Onat und 5 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the seismic performance limitations of a newly constructed reinforced concrete building that collapsed during the 6 February 2023 Kahramanmaraş–Elbistan earthquake despite formal compliance with current seismic design requirements. Beyond the specific earthquake event, the study addresses a broader scientific problem: the limited understanding of the relationship between observed damage mechanisms and nonlinear dynamic response in mid-rise reinforced concrete buildings. The first part classifies recurring structural and non-structural damage patterns identified in newly constructed RC residences. The second part presents a nonlinear fiber-based static and dynamic analysis of a collapsed mid-rise building. Nonlinear dynamic analyses were conducted using ground motion records scaled to match the site-specific elastic design spectrum defined by TBDY 2018, corresponding to predefined seismic performance levels rather than an incremental dynamic analysis framework. The results indicate that an extremely low shear wall–to–floor area ratio (0.0357%) combined with asymmetric vertical element distribution significantly amplified torsional response and local shear demands. Nonlinear dynamic analyses showed that critical shear walls exceeded Collapse Prevention limits under DD2-level excitation, while system-level shear contribution limits remained within code-defined thresholds. Dynamic base shear demand corresponded to approximately 30% of the maximum nonlinear capacity obtained from pushover analysis, indicating that localized member failure rather than global strength deficiency governed the collapse mechanism. The analytically identified critical members were consistent with the observed collapse configuration, particularly at the soft ground story. The findings demonstrate that prescriptive code compliance alone may not ensure satisfactory seismic performance when structural irregularities, torsional amplification, and detailing deficiencies coexist. The results are consistent with damage patterns reported in other recent destructive earthquakes and contribute to improving the understanding of collapse mechanisms in code-compliant RC buildings.

Zitieren

APA

Onat, O., Karaşin, İ. B., Yön, B., Varolgüneş, S., Öncü, M. E., & Uslu, A. (2026). Failure of a Code-Compliant Reinforced Concrete Building: Damage Patterns and Nonlinear Seismic Response. Buildings, 16(5), 1012. https://doi.org/10.3390/buildings16051012

Vancouver

Onat O, Karaşin İB, Yön B, Varolgüneş S, Öncü ME, Uslu A. Failure of a Code-Compliant Reinforced Concrete Building: Damage Patterns and Nonlinear Seismic Response. Buildings. 2026;16(5):1012. doi:10.3390/buildings16051012

BibTeX
@article{Onat2026,
  author = {Onat, Onur and Karaşin, İbrahim Baran and Yön, Burak and Varolgüneş, Sadık and Öncü, Mehmet Emin and Uslu, Ali},
  title = {Failure of a Code-Compliant Reinforced Concrete Building: Damage Patterns and Nonlinear Seismic Response},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {5},
  pages = {1012},
  doi = {10.3390/buildings16051012}
}
Kostenlos starten →