EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Residual Learning Enhanced Grey-Box Modelling for Indoor Temperature Prediction and IEQ Assessment

Constantin Cilibiu, Horatiu Calin Albu, Ancuta Coca Abrudan

Buildings · 01.03.2026 · 16 (5) · 964

DOI: 10.3390/buildings16050964 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 01.03.2026. Verfasst von Constantin Cilibiu und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing demand for the energy-efficient and occupant-centred operation of educational buildings requires accurate and interpretable models capable of predicting indoor environmental conditions under real operating constraints. This study proposes a residual learning-enhanced grey-box modelling framework for predicting indoor air temperature and assessing indoor environmental quality indicators in a KNX-enabled educational building operating under simple thermostatic heating control. The approach combines a reduced-order discrete-time RC thermal model with a data-driven machine learning component trained to model the next-step residual between measured and simulated indoor temperatures. High-resolution KNX monitoring data were recorded at a 5 min sampling interval over three consecutive months (October–December) during the heating season. Using a chronological 70/30 train–test split, the identified RC grey-box model achieved a pooled test RMSE of 0.269 °C, an MAE of 0.126 °C, and an R2 of 0.987. The proposed hybrid formulation achieved RMSE = 0.343 °C, MAE = 0.106 °C, and R2 = 0.978 across 62,456 test samples. While the pooled RMSE remains influenced by occasional larger deviations in a small number of rooms, the hybrid model yields a consistent reduction in absolute error (≈16% MAE reduction) and reduced inter-room variability compared to the physics-based baseline. These results indicate that residual learning can enhance predictive robustness under decentralized thermostatic operation and limited sensing, while preserving physical interpretability. The proposed framework provides a practical and scalable solution for indoor temperature prediction and IEQ assessment in educational buildings using existing KNX automation data.

Zitieren

APA

Cilibiu, C., Albu, H. C., & Abrudan, A. C. (2026). Residual Learning Enhanced Grey-Box Modelling for Indoor Temperature Prediction and IEQ Assessment. Buildings, 16(5), 964. https://doi.org/10.3390/buildings16050964

Vancouver

Cilibiu C, Albu HC, Abrudan AC. Residual Learning Enhanced Grey-Box Modelling for Indoor Temperature Prediction and IEQ Assessment. Buildings. 2026;16(5):964. doi:10.3390/buildings16050964

BibTeX
@article{Cilibiu2026,
  author = {Cilibiu, Constantin and Albu, Horatiu Calin and Abrudan, Ancuta Coca},
  title = {Residual Learning Enhanced Grey-Box Modelling for Indoor Temperature Prediction and IEQ Assessment},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {5},
  pages = {964},
  doi = {10.3390/buildings16050964}
}
Kostenlos starten →