Three-Dimensional Numerical Analyses of a Monitored Deep Excavation Pit: A Case Study in the Guangzhou Metro
Buildings · 07.11.2025 · 15 (22) · 4018
DOI: 10.3390/buildings15224018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 07.11.2025. Verfasst von Wentian Xu und 6 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Key R&D Projects in Shaanxi Province.
Abstract (Originalsprache)
This paper focuses on a deep foundation pit project of a metro shaft constructed by the cover-and-excavation reverse method in a section of Guangzhou Metro Line 13. This study integrates field monitoring data, three-dimensional finite element simulations, and parametric analyses to propose a systematic optimization design framework, providing a more comprehensive and reliable quantitative basis for the design of support structures for deep metro foundation pits constructed using the cut-and-cover top-down method. The study examines the effects of pile diameter, pile spacing, embedment depth, and types of retaining structures on pit deformation. The results indicate that increasing the pile diameter from 800 mm to 1000 mm reduces the maximum lateral displacement of the retaining structure by 30.7%, while decreasing the pile spacing from 2000 mm to 1600 mm results in a 17.5% reduction in deformation. However, beyond these thresholds, the marginal improvement becomes less significant. An embedment depth of 4 m for shallow sections and 2.5 m for deep sections is recommended to balance deformation control and construction economy. Diaphragm walls outperform bored piles and secant piles in deformation control. The optimized design achieves an estimated cost reduction of approximately 15% while maintaining safety requirements. The optimized parameters and comparative conclusions derived from this study can be directly applied to the design of deep foundation pits for metro stations under similar geological conditions. These findings provide crucial data support and theoretical reference for formulating more economical and safer design codes and standards.
Förderung
- National Natural Science Foundation of China
- Key R&D Projects in Shaanxi Province
Zitieren
APA
Xu, W., Lin, L., Zhu, N., Zhao, Y., Yang, H., Mei, Y., & Zhou, D. (2025). Three-Dimensional Numerical Analyses of a Monitored Deep Excavation Pit: A Case Study in the Guangzhou Metro. Buildings, 15(22), 4018. https://doi.org/10.3390/buildings15224018
Vancouver
Xu W, Lin L, Zhu N, Zhao Y, Yang H, Mei Y, et al. Three-Dimensional Numerical Analyses of a Monitored Deep Excavation Pit: A Case Study in the Guangzhou Metro. Buildings. 2025;15(22):4018. doi:10.3390/buildings15224018
BibTeX
@article{Xu2025,
author = {Xu, Wentian and Lin, Lifen and Zhu, Nengwen and Zhao, Yan and Yang, Hong and Mei, Yuan and Zhou, Dongbo},
title = {Three-Dimensional Numerical Analyses of a Monitored Deep Excavation Pit: A Case Study in the Guangzhou Metro},
journal = {Buildings},
year = {2025},
volume = {15},
number = {22},
pages = {4018},
doi = {10.3390/buildings15224018}
}