EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Synergistic Air Quality and Cooling Efficiency in Office Space with Indoor Green Walls

Ibtihaj Saad Rashed Alsadun, Faizah Mohammed Bashir, Zahra Andleeb, Zeineb Ben Houria, Mohamed Ahmed Said Mohamed, Oluranti Agboola

Buildings · 11.10.2025 · 15 (20) · 3656

DOI: 10.3390/buildings15203656 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 11.10.2025. Verfasst von Ibtihaj Saad Rashed Alsadun und 5 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 83 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific Research Deanship at University of Ha’il, Saudi Arabia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Enhancing indoor environmental quality while reducing building energy consumption represents a critical challenge for sustainable building design, particularly in hot arid climates where cooling loads dominate energy use. Despite extensive research on green wall systems (GWSs), robust quantitative data on their combined impact on air quality and thermal performance in real-world office environments remains limited. This research quantified the synergistic effects of an active indoor green wall system on key indoor air quality indicators and cooling energy consumption in a contemporary office environment. A comparative field study was conducted over 12 months in two identical office rooms in Dhahran, Saudi Arabia, with one room serving as a control while the other was retrofitted with a modular hydroponic green wall system. High-resolution sensors continuously monitored indoor CO2, volatile organic compounds via photoionization detection (VOC_PID; isobutylene-equivalent), and PM2.5 concentrations, alongside dedicated sub-metering of cooling energy consumption. The green wall system achieved statistically significant improvements across all parameters: 14.1% reduction in CO2 concentrations during occupied hours, 28.1% reduction in volatile organic compounds, 20.9% reduction in PM2.5, and 13.5% reduction in cooling energy consumption (574.5 kWh annually). Economic analysis indicated financial viability (2.0-year payback; benefit–cost ratio 3.0; 15-year net present value SAR 31,865). Productivity-related benefits were valued from published relationships rather than measured in this study; base-case viability remained strictly positive in energy-only and conservative sensitivity scenarios. Strong correlations were established between evapotranspiration rates and cooling benefits (r = 0.734), with peak performance during summer months reaching 17.1% energy savings. Active indoor GWSs effectively function as multifunctional strategies, delivering simultaneous air quality improvements and measurable cooling energy reductions through evapotranspiration-mediated mechanisms, supporting their integration into sustainable building design practices.

Förderung

  • Scientific Research Deanship at University of Ha’il, Saudi Arabia

Zitieren

APA

Alsadun, I. S. R., Bashir, F. M., Andleeb, Z., Houria, Z. B., Mohamed, M. A. S., & Agboola, O. (2025). Synergistic Air Quality and Cooling Efficiency in Office Space with Indoor Green Walls. Buildings, 15(20), 3656. https://doi.org/10.3390/buildings15203656

Vancouver

Alsadun ISR, Bashir FM, Andleeb Z, Houria ZB, Mohamed MAS, Agboola O. Synergistic Air Quality and Cooling Efficiency in Office Space with Indoor Green Walls. Buildings. 2025;15(20):3656. doi:10.3390/buildings15203656

BibTeX
@article{Alsadun2025,
  author = {Alsadun, Ibtihaj Saad Rashed and Bashir, Faizah Mohammed and Andleeb, Zahra and Houria, Zeineb Ben and Mohamed, Mohamed Ahmed Said and Agboola, Oluranti},
  title = {Synergistic Air Quality and Cooling Efficiency in Office Space with Indoor Green Walls},
  journal = {Buildings},
  year = {2025},
  volume = {15},
  number = {20},
  pages = {3656},
  doi = {10.3390/buildings15203656}
}
Kostenlos starten →