EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Novel Earth-to-Air Heat Exchanger-Assisted Ventilated Double-Skin Facade for Low-Grade Renewable Energy Utilization in Transparent Building Envelopes

Zhanzhi Yu, Fei Liu, Wenke Sui, Rui Wang, Chong Zhang, Xiaoxiao Dong, Xinhua Xu

Buildings · 11.10.2025 · 15 (20) · 3655

DOI: 10.3390/buildings15203655 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 11.10.2025. Verfasst von Zhanzhi Yu und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China, National Natural Science Foundation of China, Key Research and Development Program of Hubei Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transparent building envelopes significantly increase energy demands due to low thermal resistance and solar heat gain, while conventional double-skin facades may lead to overheating and high cooling loads in the summer. This study proposes a novel earth-to-air heat exchanger (EAHE)-assisted ventilated double-skin facade (VDSF) system utilizing low-grade shallow geothermal energy for year-round thermal regulation of transparent building envelopes. A numerical model of this coupled system was developed and validated to estimate the thermal performance of the EAHE-assisted VDSF system in a hot-summer-and-cold-winter climate. Parametric study was conducted to investigate the impact of some key design parameters on thermal performance of the EAHE-assisted VDSF system and further reveal recommended design parameters of this coupled system. The results indicate that the EAHE-VDSF system reduces annual accumulated cooling loads by 20.3% to 76.5% and heating loads by 19.6% to 47.1% in comparison to a conventional triple-glazed, non-ventilated facade. The cavity temperature of the VDSF decreases by 15 °C on average in the summer, effectively addressing the overheating issue in DSFs. The proposed coupled EAHE-VDSF system shows promising energy-saving potential and ensures stability and consistency in the thermal regulation of transparent building envelopes.

Förderung

  • National Key R&D Program of China
  • National Natural Science Foundation of China
  • Key Research and Development Program of Hubei Province

Zitieren

APA

Yu, Z., Liu, F., Sui, W., Wang, R., Zhang, C., Dong, X., & Xu, X. (2025). A Novel Earth-to-Air Heat Exchanger-Assisted Ventilated Double-Skin Facade for Low-Grade Renewable Energy Utilization in Transparent Building Envelopes. Buildings, 15(20), 3655. https://doi.org/10.3390/buildings15203655

Vancouver

Yu Z, Liu F, Sui W, Wang R, Zhang C, Dong X, et al. A Novel Earth-to-Air Heat Exchanger-Assisted Ventilated Double-Skin Facade for Low-Grade Renewable Energy Utilization in Transparent Building Envelopes. Buildings. 2025;15(20):3655. doi:10.3390/buildings15203655

BibTeX
@article{Yu2025,
  author = {Yu, Zhanzhi and Liu, Fei and Sui, Wenke and Wang, Rui and Zhang, Chong and Dong, Xiaoxiao and Xu, Xinhua},
  title = {A Novel Earth-to-Air Heat Exchanger-Assisted Ventilated Double-Skin Facade for Low-Grade Renewable Energy Utilization in Transparent Building Envelopes},
  journal = {Buildings},
  year = {2025},
  volume = {15},
  number = {20},
  pages = {3655},
  doi = {10.3390/buildings15203655}
}
Kostenlos starten →