Research on the Operating Performance of a Combined Heat and Power System Integrated with Solar PV/T and Air-Source Heat Pump in Residential Buildings

Haoran Ning, Fu Liang, Huaxin Wu, Zeguo Qiu, Zhipeng Fan, Bingxin Xu

Buildings · 20.07.2025 · 15 (14) · 2564

DOI: 10.3390/buildings15142564 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 20.07.2025. Verfasst von Haoran Ning und 5 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Project for the Construction of Collaborative Innovation Achievements in Disciplines, Heilongjiang Province Postdoctoral Foundation General Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Global building energy consumption is significantly increasing. Utilizing renewable energy sources may be an effective approach to achieving low-carbon and energy-efficient buildings. A combined system incorporating solar photovoltaic–thermal (PV/T) components with an air-source heat pump (ASHP) was studied for simultaneous heating and power generation in a real residential building. The back panel of the PV/T component featured a novel polygonal Freon circulation channel design. A prototype of the combined heating and power supply system was constructed and tested in Fuzhou City, China. The results indicate that the average coefficient of performance (COP) of the system is 4.66 when the ASHP operates independently. When the PV/T component is integrated with the ASHP, the average COP increases to 5.37. On sunny days, the daily average thermal output of 32 PV/T components reaches 24 kW, while the daily average electricity generation is 64 kW·h. On cloudy days, the average daily power generation is 15.6 kW·h; however, the residual power stored in the battery from the previous day could be utilized to ensure the energy demand in the system. Compared to conventional photovoltaic (PV) systems, the overall energy utilization efficiency improves from 5.68% to 17.76%. The hot water temperature stored in the tank can reach 46.8 °C, satisfying typical household hot water requirements. In comparison to standard PV modules, the system achieves an average cooling efficiency of 45.02%. The variation rate of the system’s thermal loss coefficient is relatively low at 5.07%. The optimal water tank capacity for the system is determined to be 450 L. This system demonstrates significant potential for providing efficient combined heat and power supply for buildings, offering considerable economic and environmental benefits, thereby serving as a reference for the future development of low-carbon and energy-saving building technologies.

Förderung

  • Project for the Construction of Collaborative Innovation Achievements in Disciplines
  • Heilongjiang Province Postdoctoral Foundation General Project

Zitieren

APA

Ning, H., Liang, F., Wu, H., Qiu, Z., Fan, Z., & Xu, B. (2025). Research on the Operating Performance of a Combined Heat and Power System Integrated with Solar PV/T and Air-Source Heat Pump in Residential Buildings. Buildings, 15(14), 2564. https://doi.org/10.3390/buildings15142564

Vancouver

Ning H, Liang F, Wu H, Qiu Z, Fan Z, Xu B. Research on the Operating Performance of a Combined Heat and Power System Integrated with Solar PV/T and Air-Source Heat Pump in Residential Buildings. Buildings. 2025;15(14):2564. doi:10.3390/buildings15142564

BibTeX
@article{Ning2025,
  author = {Ning, Haoran and Liang, Fu and Wu, Huaxin and Qiu, Zeguo and Fan, Zhipeng and Xu, Bingxin},
  title = {Research on the Operating Performance of a Combined Heat and Power System Integrated with Solar PV/T and Air-Source Heat Pump in Residential Buildings},
  journal = {Buildings},
  year = {2025},
  volume = {15},
  number = {14},
  pages = {2564},
  doi = {10.3390/buildings15142564}
}