EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Integrated Leakage Control Technology for Underground Structures in Karst Terrains: Multi-Stage Grouting and Zoned Remediation at Guangzhou Baiyun Metro Station

Yanhong Wang, Wentian Xu, Shi Zheng, Jinsong Liu, Muyu Li, Yili Yuan

Buildings · 26.06.2025 · 15 (13) · 2239

DOI: 10.3390/buildings15132239 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 26.06.2025. Verfasst von Yanhong Wang und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Research and Development Project of the Ministry of Housing and Urban-Rural Development.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a comprehensive treatment system for addressing leakage challenges in underground structure construction within complex karst terrains, demonstrated through the case of Baiyun Station in Guangzhou. Integrating advanced geological investigation, dynamic grouting techniques, and adaptive structural remediation strategies, this methodology effectively mitigates water inflow risks in structurally heterogeneous karst environments. Key innovations include the “one-trench two-drilling” exploration-grouting system for karst cave detection and filling, a multi-stage emergency water-gushing control protocol combining cofferdam sealing and dual-fluid grouting, and a zoned epoxy resin injection scheme for structural fissure remediation. Implementation at Baiyun Station achieved quantifiable outcomes: karst cave filling rates increased from 35.98% to 82.6%, foundation pit horizontal displacements reduced by 67–68%, and structural seepage repair rates reached 96.4%. The treatment system reduced construction costs by CNY 12 million and shortened schedules by 45 days through optimized pile formation efficiency (98% qualification rate) and minimized rework. While demonstrating superior performance in sealing > 0.2 mm fissures, limitations persist in addressing sub-micron fractures and ensuring long-term epoxy resin durability. This research establishes a replicable framework for underground engineering in karst regions, emphasizing real-time monitoring, multi-technology synergy, and environmental sustainability.

Förderung

  • National Natural Science Foundation of China
  • Research and Development Project of the Ministry of Housing and Urban-Rural Development

Zitieren

APA

Wang, Y., Xu, W., Zheng, S., Liu, J., Li, M., & Yuan, Y. (2025). Integrated Leakage Control Technology for Underground Structures in Karst Terrains: Multi-Stage Grouting and Zoned Remediation at Guangzhou Baiyun Metro Station. Buildings, 15(13), 2239. https://doi.org/10.3390/buildings15132239

Vancouver

Wang Y, Xu W, Zheng S, Liu J, Li M, Yuan Y. Integrated Leakage Control Technology for Underground Structures in Karst Terrains: Multi-Stage Grouting and Zoned Remediation at Guangzhou Baiyun Metro Station. Buildings. 2025;15(13):2239. doi:10.3390/buildings15132239

BibTeX
@article{Wang2025,
  author = {Wang, Yanhong and Xu, Wentian and Zheng, Shi and Liu, Jinsong and Li, Muyu and Yuan, Yili},
  title = {Integrated Leakage Control Technology for Underground Structures in Karst Terrains: Multi-Stage Grouting and Zoned Remediation at Guangzhou Baiyun Metro Station},
  journal = {Buildings},
  year = {2025},
  volume = {15},
  number = {13},
  pages = {2239},
  doi = {10.3390/buildings15132239}
}
Kostenlos starten →