Fachartikel in der Zeitschrift Buildings, online erschienen am 06.12.2024. Verfasst von Sai Liu und 5 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific Research Fund of Hunan Provincial Education Department.
Abstract (Originalsprache)
In the energy-saving retrofit of existing buildings, investors are particularly concerned about the energy-saving performance of exterior windows and the payback period of additional costs. This study evaluates representative cities in four different climate zones in China to simulate the energy consumption of large office buildings after replacing different glass windows and conducting energy-saving and economic feasibility assessments. The research method includes the following steps: First, a baseline model of large office buildings in four cities was established using AutoBPS and OpenStudio. Then, the baseline and retrofit models of replacing glass windows were simulated using the EnergyPlus V9.3.0 to obtain multiple hourly energy consumption results. The commercial electricity and gas prices in the four cities were adjusted to calculate the total cost within 20 years after replacing different types of windows. Using the discounted payback period (DPP), net present value (NPV), and profitability index (PI) as evaluation indicators, a feasibility analysis was conducted in the four regions to evaluate the economic feasibility of replacing building windows. The simulation results show that considering economic feasibility and meeting energy-saving standards, it is more economical to choose windows with moderate U-value and SHGC value in the four regions than to choose windows with the smallest U-value and SHGC value, and that both energy savings and economic benefits are closely related to building age, with older buildings (especially those in Changsha and Shenzhen) showing greater benefits. Furthermore, the optimal window types in the four cities determined in this study can recover the investment cost within the window life, with Harbin (SC), Beijing (C), Changsha (HC), and Shenzhen (HW) with the payback period of 6.60, 15.66, 10.16, and 11.42 years, respectively. The research model established in this study provides a useful evaluation path for selecting windows for the energy-saving retrofit of large office buildings in cities in different climate zones and provides data support for the decision making of energy-saving retrofit investors.
Förderung
- Scientific Research Fund of Hunan Provincial Education Department
Zitieren
APA
Liu, S., Ghazali, F. E. M., Yang, J., Guo, Z., Zeng, K., & Chen, Y. (2024). Retrofit Analysis of Exterior Windows for Large Office Buildings in Different Climate Zones of China. Buildings, 14(12), 3904. https://doi.org/10.3390/buildings14123904
Vancouver
Liu S, Ghazali FEM, Yang J, Guo Z, Zeng K, Chen Y. Retrofit Analysis of Exterior Windows for Large Office Buildings in Different Climate Zones of China. Buildings. 2024;14(12):3904. doi:10.3390/buildings14123904
BibTeX
@article{Liu2024,
author = {Liu, Sai and Ghazali, Farid E. Mohamed and Yang, Jingjing and Guo, Zongkang and Zeng, Kejun and Chen, Yixing},
title = {Retrofit Analysis of Exterior Windows for Large Office Buildings in Different Climate Zones of China},
journal = {Buildings},
year = {2024},
volume = {14},
number = {12},
pages = {3904},
doi = {10.3390/buildings14123904}
}