EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Flexural Behavior of Galvanized Iron Based Cold-Formed Steel Back-to-Back Built-Up Beams at Elevated Temperatures

Varun Sabu Sam, Anand Nammalvar, Diana Andrushia, Beulah Gnana Ananthi Gurupatham, Krishanu Roy

Buildings · 08.08.2024 · 14 (8) · 2456

DOI: 10.3390/buildings14082456 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 08.08.2024. Verfasst von Varun Sabu Sam und 4 weiteren Autor:innen. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cold-formed steel (CFS) sections have become popular in construction due to several advantages over structural steel. However, research on the performance of galvanized iron (GI)-based CFS under high temperatures, especially regarding its flexural behavior, has been limited. This study extensively investigates how GI-based CFS beams with varying spans behave under elevated temperatures and subsequent cooling using air and water. This study examines the impact of temperature loading and compares the effectiveness of air- and water-cooling methods. Experimental results are validated and analyzed alongside findings from finite element modeling (FEM) using ABAQUS (2019_09_13-23.19.31) and the Direct Strength Method (DSM). Additionally, this study conducts a parametric investigation to assess how beam span influences flexural capacity. Among beams heated to the same temperature, those cooled with water show slightly lower load capacities compared to those cooled with air. The highest load capacity observed is 64.3 kN for the reference specimen, while the lowest is 26.2 kN for the specimen heated for 90 min and cooled with water, a 59.27% difference between them. Stiffness decreases as heating duration increases, with the reference section exhibiting significantly higher stiffness compared to the section heated for 90 min and cooled with water, with a 92.76% difference in stiffness. As heating duration increases, ductility also increases. Various failure modes are observed based on different heating and cooling conditions across different beam spans. This study provides insights into how GI-based CFS beams perform under temperature stress and different cooling scenarios, contributing valuable data for structural design and safety considerations in construction.

Zitieren

APA

Sam, V. S., Nammalvar, A., Andrushia, D., Gurupatham, B. G. A., & Roy, K. (2024). Flexural Behavior of Galvanized Iron Based Cold-Formed Steel Back-to-Back Built-Up Beams at Elevated Temperatures. Buildings, 14(8), 2456. https://doi.org/10.3390/buildings14082456

Vancouver

Sam VS, Nammalvar A, Andrushia D, Gurupatham BGA, Roy K. Flexural Behavior of Galvanized Iron Based Cold-Formed Steel Back-to-Back Built-Up Beams at Elevated Temperatures. Buildings. 2024;14(8):2456. doi:10.3390/buildings14082456

BibTeX
@article{Sam2024,
  author = {Sam, Varun Sabu and Nammalvar, Anand and Andrushia, Diana and Gurupatham, Beulah Gnana Ananthi and Roy, Krishanu},
  title = {Flexural Behavior of Galvanized Iron Based Cold-Formed Steel Back-to-Back Built-Up Beams at Elevated Temperatures},
  journal = {Buildings},
  year = {2024},
  volume = {14},
  number = {8},
  pages = {2456},
  doi = {10.3390/buildings14082456}
}
Kostenlos starten →