EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Tensile-to-Shear Crack Transition in the Compression Failure of Steel-Fibre-Reinforced Concrete: Insights from Acoustic Emission Monitoring

Zihan Jiang, Zhiwen Zhu, Federico Accornero

Buildings · 04.07.2024 · 14 (7) · 2039

DOI: 10.3390/buildings14072039 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 04.07.2024. Verfasst von Zihan Jiang und 2 weiteren Autor:innen. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Guangdong Province, STU Outstanding Talent Grant.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Steel-fibre-reinforced concrete (SFRC) has been increasingly used in the field of engineering structures in recent years. Hence, the accurate monitoring of the fracturing process of in-service SFRC has considerable significance in terms of structural safety. This paper investigates the acoustic emission (AE) and digital image correlation (DIC) features characterising the damage behaviour of SFRC samples in compression. For all the tests, cumulated AE, b-value, βt coefficient, average frequency, and rise angle are considered to describe the actual SFRC failure mechanisms. The results show that SFRC exhibits enhanced toughness compared to normal concrete (NC), with an indicated transition from a brittle to a ductile structural behaviour. This improved behaviour can be attributed to the bridging effect of steel fibres, which also drives the progressive tensile-to-shear crack transition, thus being the main cause of the final SFRC failure. As the loading rate increases, there is a corresponding increase in the number of shear cracks, leading to a decrease in the overall ductility and toughness of SFRC. Moreover, since the number of shear cracks notably increases right before SFRC fracture, this can serve as a safety warning of the impending failure. Furthermore, the cumulated AE curve displays a strong discontinuity in the occurrence of an unstable fracturing process in SFRC, which can also be forecasted by the AE time-scaling coefficient βt. The AE and DIC features can be used as failure precursors in the field of structural surveying, offering an accurate technical support for engineering failure warnings.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Guangdong Province
  • STU Outstanding Talent Grant

Zitieren

APA

Jiang, Z., Zhu, Z., & Accornero, F. (2024). Tensile-to-Shear Crack Transition in the Compression Failure of Steel-Fibre-Reinforced Concrete: Insights from Acoustic Emission Monitoring. Buildings, 14(7), 2039. https://doi.org/10.3390/buildings14072039

Vancouver

Jiang Z, Zhu Z, Accornero F. Tensile-to-Shear Crack Transition in the Compression Failure of Steel-Fibre-Reinforced Concrete: Insights from Acoustic Emission Monitoring. Buildings. 2024;14(7):2039. doi:10.3390/buildings14072039

BibTeX
@article{Jiang2024,
  author = {Jiang, Zihan and Zhu, Zhiwen and Accornero, Federico},
  title = {Tensile-to-Shear Crack Transition in the Compression Failure of Steel-Fibre-Reinforced Concrete: Insights from Acoustic Emission Monitoring},
  journal = {Buildings},
  year = {2024},
  volume = {14},
  number = {7},
  pages = {2039},
  doi = {10.3390/buildings14072039}
}
Kostenlos starten →