Seismic Performance of Full-Scale Autoclaved Aerated Concrete Panel-Assembled Walls: Experimental Study and Numerical Modeling
Buildings · 08.05.2024 · 14 (5) · 1333
DOI: 10.3390/buildings14051333 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 08.05.2024. Verfasst von Xiaowei Li und 5 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Sichuan Province, Natural Science Foundation of Southwest University of Science and Technology, Science and Technology Planning Project of Ningbo City.
Abstract (Originalsprache)
Prefabricated panel-assembled wall systems, comprising a confining frame and infill lightweight panels of autoclaved aerated concrete (AAC), are widely employed in framed structures. Different from studies on a main frame with infill walls, this study aimed to explore the seismic performance of partition walls, which were fabricated with AAC panel-assembled walls and located outside of the main frames. Two full-scale specimens, one with a door opening and the other without, were constructed and cyclic loading tests were executed to examine the failure modes, hysteresis characteristics, envelope curves, ductility, strength and stiffness degradation, as well as energy dissipation capacity of the AAC panel-assembled walls. Additionally, a restoring-force model for the panel-assembled walls was developed and a method for predicting the lateral load-bearing capacity of the AAC panel-assembled walls was proposed. The findings indicated that the panels enhanced the system’s lateral resistance, energy dissipation capacity, and deformation capability. The door frame increased the initial stiffness, peak lateral load and energy dissipation capacity of the AAC panel-assembled wall compared to the wall without a door frame. Compared to the specimen without a door frame, the peak lateral load of the specimen with a door frame increased by 19.7–30.1%. The deformation capacity of the panel-assembled walls aligned with the requirements for concrete framed structures.
Förderung
- Natural Science Foundation of Sichuan Province
- Natural Science Foundation of Southwest University of Science and Technology
- Science and Technology Planning Project of Ningbo City
Zitieren
APA
Li, X., Ma, D., Zhang, Q., Zhang, Z., Bao, H., & Yao, Y. (2024). Seismic Performance of Full-Scale Autoclaved Aerated Concrete Panel-Assembled Walls: Experimental Study and Numerical Modeling. Buildings, 14(5), 1333. https://doi.org/10.3390/buildings14051333
Vancouver
Li X, Ma D, Zhang Q, Zhang Z, Bao H, Yao Y. Seismic Performance of Full-Scale Autoclaved Aerated Concrete Panel-Assembled Walls: Experimental Study and Numerical Modeling. Buildings. 2024;14(5):1333. doi:10.3390/buildings14051333
BibTeX
@article{Li2024,
author = {Li, Xiaowei and Ma, Dongwen and Zhang, Qidi and Zhang, Zhaoqiang and Bao, Han and Yao, Yong},
title = {Seismic Performance of Full-Scale Autoclaved Aerated Concrete Panel-Assembled Walls: Experimental Study and Numerical Modeling},
journal = {Buildings},
year = {2024},
volume = {14},
number = {5},
pages = {1333},
doi = {10.3390/buildings14051333}
}
EUVIMED