Retrofit Measures for Achieving NZE Single-Family Houses in a Tropical Climate via Multi-Objective Optimization
Buildings · 20.02.2024 · 14 (3) · 566
DOI: 10.3390/buildings14030566 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 20.02.2024. Verfasst von Cristina Carpino und 3 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Panamanian Institution Secretaría Nacional de Ciencia, Tecnología e Innovación SENACYT, Sistema Nacional de Investigación (SNI).
Abstract (Originalsprache)
To achieve sustainable cities and communities, it is necessary to decarbonize existing buildings. Actions need to be taken to reduce the buildings’ energy demand and ensure that the low remaining demand is met by energy produced from renewable sources. This leads to Net Zero Energy Buildings (NZEBs), whose impact on energy consumption is zero or positive, meaning that they are able to produce more energy than they require. The “zero” objective may be difficult to reach in hot and humid climates, where the cooling demand is prevalent. In this case, a combination of active and passive measures, together with appropriate interaction with users, is a viable way to obtain NZEBs. The present study aims to explore technological solutions for renovating existing buildings to NZEBs in a tropical climate. The analysis is developed through a parametric analysis, a sensitivity analysis, and an optimization directed at minimizing the site’s net energy and hours of discomfort. Evaluations are conducted for a case study consisting of a single-family house located in Panama City. The results showed that photovoltaic size, cooling operation schedule, and cooling set-point temperature are the most influential variables for the attainment of NZEBs in a hot climate. Regarding the building envelope, the outcomes suggest the low insulation of dispersing structures and local solar shading of windows as recommended measures.
Förderung
- Panamanian Institution Secretaría Nacional de Ciencia, Tecnología e Innovación SENACYT
- Sistema Nacional de Investigación (SNI)
Zitieren
APA
Carpino, C., Austin, M. C., Mora, D., & Arcuri, N. (2024). Retrofit Measures for Achieving NZE Single-Family Houses in a Tropical Climate via Multi-Objective Optimization. Buildings, 14(3), 566. https://doi.org/10.3390/buildings14030566
Vancouver
Carpino C, Austin MC, Mora D, Arcuri N. Retrofit Measures for Achieving NZE Single-Family Houses in a Tropical Climate via Multi-Objective Optimization. Buildings. 2024;14(3):566. doi:10.3390/buildings14030566
BibTeX
@article{Carpino2024,
author = {Carpino, Cristina and Austin, Miguel Chen and Mora, Dafni and Arcuri, Natale},
title = {Retrofit Measures for Achieving NZE Single-Family Houses in a Tropical Climate via Multi-Objective Optimization},
journal = {Buildings},
year = {2024},
volume = {14},
number = {3},
pages = {566},
doi = {10.3390/buildings14030566}
}