Cyclic Loading Test Conducted on the Bottom Joints of a Hybrid Precast Utility Tunnel Composed of Double-Skin Sidewalls and a Precast Bottom Slab
Buildings · 26.01.2024 · 14 (2) · 341
DOI: 10.3390/buildings14020341 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 26.01.2024. Verfasst von Weichen Xue und 2 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program.
Abstract (Originalsprache)
Four full-scale specimens were constructed, including two hybrid precast specimens with a haunch (height: 150 mm, PUT-H) and without a haunch (PUT). Additionally, two cast-in-place (CIP) comparative specimens (referred to as RUT-H and RUT) were included, all of which underwent reversed cyclic loading. The results showed that the four specimens suffered flexural damage at the ends of the sidewall and displayed similar hysteresis loops shapes. The bearing capacity of the PUT specimen was 2.7% higher than that of the RUT, while the bearing capacity of the PUT-H specimen was 8.5% lower than that of the RUT-H. Additionally, the displacement ductility values of the precast specimens PUT and PUT-H were 2.98 and 2.46, respectively, which are 11.3% and 3.53% lower than those of the corresponding CIP specimens. The haunch increases the local stiffness of the component, exerting a notable influence on the bearing capacity and displacement ductility of the specimens, increasing the bearing capacity by 20% and decreasing the ductility by 21%. Moreover, an assessment conducted using the criteria outlined in ACI 374.1-05 indicated that the four specimens exhibit excellent seismic performance.
Förderung
- National Key Research and Development Program
Zitieren
APA
Xue, W., Chen, S., & Wang, Q. (2024). Cyclic Loading Test Conducted on the Bottom Joints of a Hybrid Precast Utility Tunnel Composed of Double-Skin Sidewalls and a Precast Bottom Slab. Buildings, 14(2), 341. https://doi.org/10.3390/buildings14020341
Vancouver
Xue W, Chen S, Wang Q. Cyclic Loading Test Conducted on the Bottom Joints of a Hybrid Precast Utility Tunnel Composed of Double-Skin Sidewalls and a Precast Bottom Slab. Buildings. 2024;14(2):341. doi:10.3390/buildings14020341
BibTeX
@article{Xue2024,
author = {Xue, Weichen and Chen, Shengyang and Wang, Qinghua},
title = {Cyclic Loading Test Conducted on the Bottom Joints of a Hybrid Precast Utility Tunnel Composed of Double-Skin Sidewalls and a Precast Bottom Slab},
journal = {Buildings},
year = {2024},
volume = {14},
number = {2},
pages = {341},
doi = {10.3390/buildings14020341}
}
EUVIMED