Collaborative Optimized Design of Glazing Parameters and PCM Utilization for Energy-Efficient Glass Curtain Wall Buildings
Buildings · 17.01.2024 · 14 (1) · 256
DOI: 10.3390/buildings14010256 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 17.01.2024. Verfasst von Xinrui Zheng und 4 weiteren Autor:innen. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of China, Shenzhen Science and Technology Program, National College Student Innovation and Entrepreneurship Training Program.
Abstract (Originalsprache)
Glass curtain walls (GCWs) have become prevalent in office buildings, owing to their lightweight and modular characteristics. However, their lower thermal resistance, compared to opaque walls, results in increased energy consumption. Incorporating phase-change materials (PCMs) provides a viable solution through which to address the susceptibility of GCWs to external conditions, thus enhancing thermal performance and mitigating energy concerns. This study delves into the influences of the glazing solar heat gain coefficient (SHGC), the glazing heat transfer coefficient (U-value), and PCM thickness on the energy performance of buildings. Using Design Builder (DB) software version 6.1.0.006, a multi-story office building was simulated in different climatic zones in China, covering the climatic characteristics of severe cold, cold, hot summer and warm winter, cold summer and winter, and mild regions. The simulation results quantitatively elucidated the effects of the glazing parameters and the number of PCMs on thermal regulation and energy consumption. A sensitivity analysis identified the glazing SHGC as the most influential factor in energy consumption. Additionally, by employing Response Surface Methodology (RSM), the researchers aimed to achieve a balance between minimal building energy consumption and economic cost, ultimately determining an optimal design solution. The results demonstrated significant energy savings, ranging from 20.16% to 81.18%, accompanied by economic savings, ranging from 15.78% to 79.54%, across distinct climate zones in China.
Förderung
- Natural Science Foundation of China
- Shenzhen Science and Technology Program
- National College Student Innovation and Entrepreneurship Training Program
Zitieren
APA
Zheng, X., Liang, Y., Yang, H., Zeng, Y., & Cui, H. (2024). Collaborative Optimized Design of Glazing Parameters and PCM Utilization for Energy-Efficient Glass Curtain Wall Buildings. Buildings, 14(1), 256. https://doi.org/10.3390/buildings14010256
Vancouver
Zheng X, Liang Y, Yang H, Zeng Y, Cui H. Collaborative Optimized Design of Glazing Parameters and PCM Utilization for Energy-Efficient Glass Curtain Wall Buildings. Buildings. 2024;14(1):256. doi:10.3390/buildings14010256
BibTeX
@article{Zheng2024,
author = {Zheng, Xinrui and Liang, Yan and Yang, Haibin and Zeng, Yingyan and Cui, Hongzhi},
title = {Collaborative Optimized Design of Glazing Parameters and PCM Utilization for Energy-Efficient Glass Curtain Wall Buildings},
journal = {Buildings},
year = {2024},
volume = {14},
number = {1},
pages = {256},
doi = {10.3390/buildings14010256}
}
EUVIMED