EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In-Situ Test and Numerical Simulation of Anchoring Performance of Embedded Rock GFRP Anchor

Zengming Hao, Honghua Liu, Nan Yan, Zhongsheng Wang, Xiaoyu Bai, Jianyong Han, Chunrong Mi, Shixiang Jia, Gan Sun, Lei Zhu, Mingyi Zhang

Buildings · 08.11.2023 · 13 (11) · 2799

DOI: 10.3390/buildings13112799 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 08.11.2023. Verfasst von Zengming Hao und 10 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Key Program of Natural Science Foundation of Shandong Province, Key Laboratory of Geological Safety of Coastal Urban Underground Space, Ministry of Natural Resources, Open Fund Key Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Compared to traditional steel reinforcement, GFRP anchors demonstrate outstanding mechanical performance and corrosion resistance, and so they are an ideal substitute for steel reinforcement in anti-floating projects. Based on finite element software, a 3D axisymmetric calculation model of GFRP anti-floating anchors in medium-weathered granite was established in this paper. Combined with the in-situ ultimate pull-out tests, the bonding anchoring performance and bearing characteristics between the anchor body, anchoring mortar, and rock–soil mass were analyzed. The research findings indicated that the cohesive bonding elements exhibited a high degree of conformity in defining the interface contact relationship of the GFRP anti-floating anchor anchoring system. The axial force of the GFRP anti-floating anchor body is “attenuated” along the depth direction, and there was a critical value of anchoring length; under the same conditions, the reasonable anchoring length should be 3.5~5.0 m. All the anchors in the in-situ tests exhibited interfacial shear slip failure between the anchor body and the anchor mortar, with an average maximum load of 450 kN, which is consistent with the maximum failure load of the simulated anchors. Compared to a load of 50 kN, the maximum stress of the anchor mortar increased by 50% under a load of 450 kN. The displacement variation of the surrounding rock–soil mass showed a decreasing trend from the inside to the outside and from the top to the bottom. The research results provided valuable references for the optimization design of GFRP anti-floating anchors.

Förderung

  • National Natural Science Foundation of China
  • Key Program of Natural Science Foundation of Shandong Province
  • Key Laboratory of Geological Safety of Coastal Urban Underground Space, Ministry of Natural Resources, Open Fund Key Project
  • Taishan Scholars
  • Shandong Province, and the China Postdoctoral Science Foundation Funding

Zitieren

APA

Hao, Z., Liu, H., Yan, N., Wang, Z., Bai, X., Han, J., Mi, C., Jia, S., Sun, G., Zhu, L., & Zhang, M. (2023). In-Situ Test and Numerical Simulation of Anchoring Performance of Embedded Rock GFRP Anchor. Buildings, 13(11), 2799. https://doi.org/10.3390/buildings13112799

Vancouver

Hao Z, Liu H, Yan N, Wang Z, Bai X, Han J, et al. In-Situ Test and Numerical Simulation of Anchoring Performance of Embedded Rock GFRP Anchor. Buildings. 2023;13(11):2799. doi:10.3390/buildings13112799

BibTeX
@article{Hao2023,
  author = {Hao, Zengming and Liu, Honghua and Yan, Nan and Wang, Zhongsheng and Bai, Xiaoyu and Han, Jianyong and Mi, Chunrong and Jia, Shixiang and Sun, Gan and Zhu, Lei and Zhang, Mingyi},
  title = {In-Situ Test and Numerical Simulation of Anchoring Performance of Embedded Rock GFRP Anchor},
  journal = {Buildings},
  year = {2023},
  volume = {13},
  number = {11},
  pages = {2799},
  doi = {10.3390/buildings13112799}
}