EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hygrothermal Performance of Bio-Based Exterior Wall Constructions and Their Resilience under Air Leakage and Moisture Load

Henriette Fischer, Azra Korjenic

Buildings · 21.10.2023 · 13 (10) · 2650

DOI: 10.3390/buildings13102650 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 21.10.2023. Verfasst von Henriette Fischer und 1 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Labour and Economic Affairs (BMAW) of Austria in the FFG programme COIN Networks, TU Wien Bibliothek.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of renewable building materials in construction is crucial to minimising the environmental impact of new buildings. Bio-based building materials have a wide range of positive properties, many of which are due to their hygroscopic behaviour. The purpose of this study is to investigate the hygrothermal performance of chopped straw, sheep’s wool, and cellulose insulated timber frame external wall assemblies in the presence of air leakage and high indoor relative humidity. For this purpose, tests with different moisture contents, overpressures, and defects in the airtight layer were carried out in an outdoor test stand over a period of 18 months. The results were compared with a conventional mineral wool insulated construction. Both sheep’s wool and cellulose are particularly fault-tolerant insulation materials in combination with timber frame constructions. All three bio-based insulations, despite defects in the airtight layer, showed no mould-prone moisture content. An installation level insulated with sheep’s wool can increase the fault tolerance of constructions with insulation made of hygric and more sensitive building materials. For chopped straw and cellulose, the measured U-value was lower than expected. Further in situ measurements of bio-based structures are important to gain confidence in their hygrothermal behaviour and to increase their use in multi-storey construction.

Förderung

  • Federal Ministry of Labour and Economic Affairs (BMAW) of Austria in the FFG programme COIN Networks
  • TU Wien Bibliothek

Zitieren

APA

Fischer, H., & Korjenic, A. (2023). Hygrothermal Performance of Bio-Based Exterior Wall Constructions and Their Resilience under Air Leakage and Moisture Load. Buildings, 13(10), 2650. https://doi.org/10.3390/buildings13102650

Vancouver

Fischer H, Korjenic A. Hygrothermal Performance of Bio-Based Exterior Wall Constructions and Their Resilience under Air Leakage and Moisture Load. Buildings. 2023;13(10):2650. doi:10.3390/buildings13102650

BibTeX
@article{Fischer2023,
  author = {Fischer, Henriette and Korjenic, Azra},
  title = {Hygrothermal Performance of Bio-Based Exterior Wall Constructions and Their Resilience under Air Leakage and Moisture Load},
  journal = {Buildings},
  year = {2023},
  volume = {13},
  number = {10},
  pages = {2650},
  doi = {10.3390/buildings13102650}
}
Kostenlos starten →