The Influence of the Prestressing Level of the Fully Threaded Anchor Bar on the Corrosion Rate
Buildings · 23.06.2023 · 13 (7) · 1592
DOI: 10.3390/buildings13071592 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 23.06.2023. Verfasst von Michal Zahuranec und 2 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: project of Operational Programme Integrated Infrastructure: Application of innovative technologies focused on the interaction of engineering constructions of t…, European Regional Development Fund, Slovak Grant Agency.
Abstract (Originalsprache)
The article presents experimental research on the corrosion of prestressing steel bars with denotation CKT (fully threaded anchor bars), which are composed of high-quality prestressing steel of the grade Y 1050 (1050 MPa). The experiment was performed using an electrochemical accelerated test. The aspects of the electric current value influence, time dependence on the degree of corrosion, and especially the influence of the prestressing level in the prestressing steel bars on the degree of corrosion were observed and examined. The results of the experiment showed that if the sample was in a stressed state, its degree of corrosion increased. Specifically, for the maximal stress equal to 90% of the tensile strength, the corrosion degree was increased by approximately 7.3%, in comparison to the unstressed specimen. In this case, a 7.3% corrosion degree corresponds to a weight loss of 350 g. The theoretical degree of corrosion was calculated using Faraday’s Law, which allowed the prediction of a rough estimate of the corrosion degree obtained with known input data. The experimental results showed that there was no apparent difference in the corrosion morphology of the sample during the same time-dependent corrosion influence at the same prestressing level in the sample with the same electric current value.
Förderung
- project of Operational Programme Integrated Infrastructure: Application of innovative technologies focused on the interaction of engineering constructions of t…
- European Regional Development Fund
- Slovak Grant Agency
Zitieren
APA
Zahuranec, M., Koteš, P., & Kraľovanec, J. (2023). The Influence of the Prestressing Level of the Fully Threaded Anchor Bar on the Corrosion Rate. Buildings, 13(7), 1592. https://doi.org/10.3390/buildings13071592
Vancouver
Zahuranec M, Koteš P, Kraľovanec J. The Influence of the Prestressing Level of the Fully Threaded Anchor Bar on the Corrosion Rate. Buildings. 2023;13(7):1592. doi:10.3390/buildings13071592
BibTeX
@article{Zahuranec2023,
author = {Zahuranec, Michal and Koteš, Peter and Kraľovanec, Jakub},
title = {The Influence of the Prestressing Level of the Fully Threaded Anchor Bar on the Corrosion Rate},
journal = {Buildings},
year = {2023},
volume = {13},
number = {7},
pages = {1592},
doi = {10.3390/buildings13071592}
}