Chloride Ion Corrosion Resistance of Innovative Self-Healing SMA Fiber-Reinforced Engineering Cementitious Composites under Dry-Wet Cycles for Ocean Structures
Buildings · 14.02.2023 · 13 (2) · 518
DOI: 10.3390/buildings13020518 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 14.02.2023. Verfasst von Weihong Chen und 5 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Fujian Province, Key Projects of Fujian Provincial Department of Transportation.
Abstract (Originalsprache)
To evaluate the chloride ion corrosion resistance of proposed innovative self-healing concrete based on shape memory alloys (SMA) and engineering cementitious composites (ECC), a total of 2 kinds of 22 specimens were prepared. Chloride ion corrosion tests of self-healing SMA-ECC concrete under dry-wet cycles were carried out. It was found that the chloride ion erosion depths of SMA-ECC were significantly smaller than that of MC, and the growth rate of erosion depth of SMA-ECC was obviously smaller than that of MC after 15 dry-wet (dry and wet) corrosion cycles. The chloride ion content of SMA-ECC vanished at the erosion depth more than 10 mm, which was consistent with the test result of AgNO3 solution color-rendering test. Test results indicate that, compared to marine concrete (MC), SMA-ECC has a better chloride ion corrosion resistance behavior. Moreover, the chloride ion concentration of SMA-ECC at a chloride ion erosion depth of less than 10 mm decreased more significantly than that of MC, indicating that almost all chloride salt solution reacted in the outer layer of SMA-ECC, which is consistent with the conclusions of 4.1 and 4.2. Finally, based on the erosion distribution of chloride ions and Fick’s second law, a calculation model describing the relationship between the apparent chloride ion diffusion coefficient and the boundary condition of the chloride ion content was proposed.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Fujian Province
- Key Projects of Fujian Provincial Department of Transportation
- University of Henan Province
Zitieren
APA
Chen, W., Liu, Y., Qian, H., Wu, P., Wu, Y., & Liu, F. (2023). Chloride Ion Corrosion Resistance of Innovative Self-Healing SMA Fiber-Reinforced Engineering Cementitious Composites under Dry-Wet Cycles for Ocean Structures. Buildings, 13(2), 518. https://doi.org/10.3390/buildings13020518
Vancouver
Chen W, Liu Y, Qian H, Wu P, Wu Y, Liu F. Chloride Ion Corrosion Resistance of Innovative Self-Healing SMA Fiber-Reinforced Engineering Cementitious Composites under Dry-Wet Cycles for Ocean Structures. Buildings. 2023;13(2):518. doi:10.3390/buildings13020518
BibTeX
@article{Chen2023,
author = {Chen, Weihong and Liu, Yi and Qian, Hui and Wu, Peng and Wu, Yingxiong and Liu, Fanghao},
title = {Chloride Ion Corrosion Resistance of Innovative Self-Healing SMA Fiber-Reinforced Engineering Cementitious Composites under Dry-Wet Cycles for Ocean Structures},
journal = {Buildings},
year = {2023},
volume = {13},
number = {2},
pages = {518},
doi = {10.3390/buildings13020518}
}