Review of Parameters Measured to Characterize Classrooms’ Indoor Environmental Quality
Buildings · 03.02.2023 · 13 (2) · 433
DOI: 10.3390/buildings13020433 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 03.02.2023. Verfasst von Minh Tien Tran und 7 weiteren Autor:innen. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 123 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: French Agency for Ecological Transition (ADEME), Scientific and Technical Centre for Building (CSTB).
Abstract (Originalsprache)
As attention to indoor environmental quality (IEQ) grows, a systematic strategy for assessing IEQ in schools needs to be developed. For this purpose, this paper presents a summary of parameters measured in school classrooms to characterize the quality of thermal, acoustic, and visual environments and indoor air quality (IAQ). The summary is based on a review of published literature reporting measurements in schools in Europe and North America in the past ten years. It also summarizes the measurement protocols and measured concentrations. Eighty-eight papers describing measurements in schools were identified and analyzed. No unique standardized measuring method was used in the reviewed studies and different parameters were measured. The most often measured parameters were those describing the thermal environment and IAQ. The former mainly comprised air temperature and relative humidity. The latter mainly comprised concentrations of carbon dioxide, particulate matter, radon, formaldehyde, and some volatile organic compounds. The measured parameters describing acoustic and visual environments mainly comprised noise level, reverberation time, and illuminance. A few studies reported additional measurements of radiant temperature, operative temperature, and speech intelligibility. Measurement protocols from different studies show inconsistency in sampling duration and location and expressed results. Measured concentrations also show high variation between studies, with some pollutants exceeding the threshold values proposed by local and/or international organizations such as the World Health Organization (WHO). This review provides the reference for developing a rating scheme and protocols for uniform characterization of classroom IEQ.
Förderung
- French Agency for Ecological Transition (ADEME)
- Scientific and Technical Centre for Building (CSTB)
Zitieren
APA
Tran, M. T., Wei, W., Dassonville, C., Martinsons, C., Ducruet, P., Mandin, C., Héquet, V., & Wargocki, P. (2023). Review of Parameters Measured to Characterize Classrooms’ Indoor Environmental Quality. Buildings, 13(2), 433. https://doi.org/10.3390/buildings13020433
Vancouver
Tran MT, Wei W, Dassonville C, Martinsons C, Ducruet P, Mandin C, et al. Review of Parameters Measured to Characterize Classrooms’ Indoor Environmental Quality. Buildings. 2023;13(2):433. doi:10.3390/buildings13020433
BibTeX
@article{Tran2023,
author = {Tran, Minh Tien and Wei, Wenjuan and Dassonville, Claire and Martinsons, Christophe and Ducruet, Pascal and Mandin, Corinne and Héquet, Valérie and Wargocki, Pawel},
title = {Review of Parameters Measured to Characterize Classrooms’ Indoor Environmental Quality},
journal = {Buildings},
year = {2023},
volume = {13},
number = {2},
pages = {433},
doi = {10.3390/buildings13020433}
}
EUVIMED