EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Discriminating Between Hydroxycinnamic and Hydroxybenzoic Acids with an Electrochemical Laccase-Based Biosensor

Totka Dodevska, Petar Slavov, Mariana Nikolova, Ilia Iliev, Nina Dimcheva

Biosensors · 19.11.2026 · 16 (11) · 666

DOI: 10.3390/bios16110666 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 19.11.2026. Verfasst von Totka Dodevska und 4 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: BG Programme PRIDST.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Laccase enzyme is recognised for its ability to selectively oxidise o- or p-diphenolic compounds in the presence of molecular oxygen. Because some of these compounds are natural antioxidants with limited water solubility, this study presents an optimised laccase-based electrochemical biosensor operating in a mixed medium (ethanol–aqueous buffer). The catalytic action of the enzyme on syringic, caffeic, chlorogenic, ferulic, and p-coumaric acids was examined by cyclic voltammetry, revealing that the first three phenolic acids effectively mediated electron transport between the laccase active site and the electrode surface, while the interaction between the enzyme and either ferulic or p-coumaric acids was not electrochemically detectable. Furthermore, the sensitivity, linear dynamic range, and limits of detection and quantification for the first three acids were determined by amperometry at a constant potential. Both hydroxycinnamic acids—caffeic and chlorogenic—can be sensed at an applied potential of 0.2 V (vs. Ag|AgCl) or lower, while syringic acid (a hydroxybenzoic acid) is detectable at −0.3 V or lower. Building on these studies, a methodology was developed and applied to discriminate between hydroxycinnamic and hydroxybenzoic acids and quantify them in alcoholic extracts of coffee and wild cranberries. The biosensing results were compared with those obtained by chromatography, with the analytical results matching from 81% to 95% the ones obtained by HPLC.

Förderung

  • BG Programme PRIDST

Zitieren

APA

Dodevska, T., Slavov, P., Nikolova, M., Iliev, I., & Dimcheva, N. (2026). Discriminating Between Hydroxycinnamic and Hydroxybenzoic Acids with an Electrochemical Laccase-Based Biosensor. Biosensors, 16(11), 666. https://doi.org/10.3390/bios16110666

Vancouver

Dodevska T, Slavov P, Nikolova M, Iliev I, Dimcheva N. Discriminating Between Hydroxycinnamic and Hydroxybenzoic Acids with an Electrochemical Laccase-Based Biosensor. Biosensors. 2026;16(11):666. doi:10.3390/bios16110666

BibTeX
@article{Dodevska2026,
  author = {Dodevska, Totka and Slavov, Petar and Nikolova, Mariana and Iliev, Ilia and Dimcheva, Nina},
  title = {Discriminating Between Hydroxycinnamic and Hydroxybenzoic Acids with an Electrochemical Laccase-Based Biosensor},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {666},
  doi = {10.3390/bios16110666}
}
Kostenlos starten →