Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 17.11.2026. Verfasst von Eslam Abubakr und 3 weiteren Autor:innen. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: New Energy and Industrial Technology Development Organization, Ministry of Education, Culture, Sports, Science and Technology, Grant-in-Aid for Scientific Research.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional gas sensors suffer from poor selectivity, high operating temperatures, or reliance on bulky spectrometers and cooled infrared detectors, limiting compact, real-time analysis. Plasmon-induced hot-electron injection across a metal/semiconductor junction offers a route to sub-bandgap photodetection without an external bias. Here, we demonstrate an angle-resolved, filter-array-free near-infrared (NIR) reconstructive spectroscopy approach based on a single embedded-grating plasmonic photodetector. Gold supports the grating-coupled surface plasmon resonance, while a thin Ti interlayer improves the interface and yields an effective Schottky barrier height of 0.506 eV, enabling internal photoemission below the silicon bandgap. An embedded grating, formed by directly grooving the silicon surface, increases the metal/semiconductor interfacial area available for hot-electron injection. Zero-bias responsivities of 4 mA/W at 1200 nm and 0.62 mA/W at 1600 nm were measured, and resonant photoresponse was additionally observed up to 2.4 µm with high spectral selectivity. Using a measured angle–wavelength responsivity matrix, high-fidelity spectral reconstruction comparable to that of commercial Fourier-transform infrared spectrometers was demonstrated at room temperature. In the present demonstration, the detector chip requires no filter array, with high potential for compact NIR spectroscopic sensors and gas monitoring applications.

Förderung

  • New Energy and Industrial Technology Development Organization
  • Ministry of Education, Culture, Sports, Science and Technology
  • Grant-in-Aid for Scientific Research

Zitieren

APA

Abubakr, E., Saito, S., Suzuki, H., & Kan, T. (2026). Filter-Array-Free Broadband NIR Reconstructive Spectroscopy via a Titanium-Engineered Self-Powered Plasmonic Photodetector. Biosensors, 16(11), 658. https://doi.org/10.3390/bios16110658

Vancouver

Abubakr E, Saito S, Suzuki H, Kan T. Filter-Array-Free Broadband NIR Reconstructive Spectroscopy via a Titanium-Engineered Self-Powered Plasmonic Photodetector. Biosensors. 2026;16(11):658. doi:10.3390/bios16110658

BibTeX
@article{Abubakr2026,
  author = {Abubakr, Eslam and Saito, Shiro and Suzuki, Hironori and Kan, Tetsuo},
  title = {Filter-Array-Free Broadband NIR Reconstructive Spectroscopy via a Titanium-Engineered Self-Powered Plasmonic Photodetector},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {658},
  doi = {10.3390/bios16110658}
}
Kostenlos starten →