Flexible Nano-Platinum Microelectrode Arrays for Sensitive and Spatially Resolved Nitric Oxide Monitoring
Biosensors · 14.11.2026 · 16 (11) · 654
DOI: 10.3390/bios16110654 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 14.11.2026. Verfasst von Umisha Siwakoti und 6 weiteren Autor:innen. Die Arbeit nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NSF Career Award.
Abstract (Originalsprache)
Nitric oxide (NO) regulates neuronal signaling and neurovascular function, but its rapid diffusion, short lifetime, and reactivity complicate real-time detection in tissue. We developed flexible platinum microelectrode arrays (MEAs) modified with nanostructured platinum (nano-Pt) and a permselective poly(m-phenylenediamine) (mPD) coating for sensitive, selective NO monitoring. Nano-Pt electrodeposition reduced impedance approximately eightfold at 10 Hz and increased charge-storage capacity approximately 7.4-fold without increasing electrode dimensions. Simultaneous amperometric recordings from multiple electrode channels demonstrated the multisite sensing proof of concept of the flexible MEA platform. Amperometric calibration showed linear responses from 50 to 250 nM (R2 > 0.999), with a sensitivity of 243.16 ± 6.12 pA/µM and an operational detection limit of 50 nM. The mPD coating attenuated responses to ascorbic acid, uric acid, and dopamine. Sensors retained NO sensitivity (180 ± 8.6 pA/µM) in endothelial cell culture medium and detected transients following exposure of primary brain microvascular endothelial cells to copper-containing high-aspect-ratio structures (CuHARS), corresponding to peak NO-equivalent concentrations of 320 ± 50 nM. In mouse hippocampus, local NMDA/glycine administration evoked responses corresponding to estimated NO concentrations of 154 ± 31 nM. Finite-element simulations predicted detectable NO concentration gradients across neighboring electrode sites. These results support flexible nano-Pt/mPD MEAs for NO monitoring in complex biological environments and motivate experimental validation of spatially resolved measurements.
Förderung
- NSF Career Award
Zitieren
APA
Siwakoti, U., Shah, O., Pandit, M., Rugg, K., DeCoster, M. A., Jones, S. A., & Castagnola, E. (2026). Flexible Nano-Platinum Microelectrode Arrays for Sensitive and Spatially Resolved Nitric Oxide Monitoring. Biosensors, 16(11), 654. https://doi.org/10.3390/bios16110654
Vancouver
Siwakoti U, Shah O, Pandit M, Rugg K, DeCoster MA, Jones SA, et al. Flexible Nano-Platinum Microelectrode Arrays for Sensitive and Spatially Resolved Nitric Oxide Monitoring. Biosensors. 2026;16(11):654. doi:10.3390/bios16110654
BibTeX
@article{Siwakoti2026,
author = {Siwakoti, Umisha and Shah, Oshima and Pandit, Manoj and Rugg, Kyle and DeCoster, Mark A. and Jones, Steven Amos and Castagnola, Elisa},
title = {Flexible Nano-Platinum Microelectrode Arrays for Sensitive and Spatially Resolved Nitric Oxide Monitoring},
journal = {Biosensors},
year = {2026},
volume = {16},
number = {11},
pages = {654},
doi = {10.3390/bios16110654}
}
EUVIMED