Magnetic Relaxation Measurements of Ex Vivo Human Liver Specimens Using a SERF Magnetometer
Biosensors · 07.11.2026 · 16 (11) · 639
DOI: 10.3390/bios16110639 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 07.11.2026. Verfasst von Kexun Tang und 9 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Open Project of the State Key Laboratory of Ocean Sensing, Zhejiang Provincial Xinmiao Talents Program.
Abstract (Originalsprache)
Reliable assessment of liver iron concentration (LIC) is important for diagnosing and monitoring iron overload disorders. We used a spin exchange relaxation free (SERF) atomic magnetometer to record magnetic relaxation signals from resected human liver tissue. A total of 23 specimens from 20 patients, including normal, fatty, cirrhotic, and hepatocellular carcinoma (HCC) liver, were polarized with a Helmholtz coil inside a magnetic shield, and the field decay after switch off was recorded. For each specimen, a water-referenced, mass-normalized relaxation amplitude ΔB (pT/g) was derived. ΔB was compared with the HISTO-derived water transverse relaxation rates, R2water, from the patients’ clinical MRI. For HCC, SERF measurements were made on resected tumor tissue, whereas MRI sampled non-cancerous liver parenchyma in the same patient. Within each category, ΔB increased with R2water and rank order agreed fully in three of the four categories. Slope differences between categories were significant with conventional standard errors but not with heteroscedasticity-consistent (HC3) standard errors and are therefore regarded as exploratory. These measurements establish a SERF workflow for comparing post-polarization magnetic relaxation amplitudes across resected human liver specimens.
Förderung
- National Natural Science Foundation of China
- Open Project of the State Key Laboratory of Ocean Sensing
- Zhejiang Provincial Xinmiao Talents Program
Zitieren
APA
Tang, K., Zheng, J., Zhou, Y., Zhang, D., Ren, C., Chen, M., Yu, F., Ruan, Y., Lin, Q., & Liang, X. (2026). Magnetic Relaxation Measurements of Ex Vivo Human Liver Specimens Using a SERF Magnetometer. Biosensors, 16(11), 639. https://doi.org/10.3390/bios16110639
Vancouver
Tang K, Zheng J, Zhou Y, Zhang D, Ren C, Chen M, et al. Magnetic Relaxation Measurements of Ex Vivo Human Liver Specimens Using a SERF Magnetometer. Biosensors. 2026;16(11):639. doi:10.3390/bios16110639
BibTeX
@article{Tang2026,
author = {Tang, Kexun and Zheng, Junhao and Zhou, Yuxin and Zhang, Dongzi and Ren, Chao and Chen, Meijie and Yu, Feidan and Ruan, Yi and Lin, Qiang and Liang, Xiao},
title = {Magnetic Relaxation Measurements of Ex Vivo Human Liver Specimens Using a SERF Magnetometer},
journal = {Biosensors},
year = {2026},
volume = {16},
number = {11},
pages = {639},
doi = {10.3390/bios16110639}
}
EUVIMED