Systematic Evaluation of a Two-Layer LF1/pH-Indicator Paper Assay for Serum Cholinesterase: Influence of Assay Conditions and Sample Background
Biosensors · 03.11.2026 · 16 (11) · 628
DOI: 10.3390/bios16110628 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 03.11.2026. Verfasst von Jessica Zúñiga-Hernández und 6 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chilean National Agency for Research and Development.
Abstract (Originalsprache)
Paper-based colorimetric devices could support decentralized screening of cholinesterase inhibition after organophosphate (OP) exposure. We systematically evaluated how substrate identity, concentration and volume, reagent hydration, reading time, glycerol addition, and serum volume affect color development in a two-layer platform comprising a glass-fiber (LF1) reaction layer and a pH-indicator detection layer. Acetylcholine chloride (AChCl), butyrylcholine chloride (BChCl), and butyrylcholine iodide were first screened in solution; AChCl and BChCl were then tested on paper with commercial serum and six individual human sera, and color was quantified as blue-channel intensity from scanned images of the pH-indicator. A working configuration using 8 µL of 60 mM substrate, with readings taken after 20 min, was selected based on the observed colorimetric response. AChCl and BChCl did not differ significantly under these conditions, and larger serum volumes gave no consistent improvement. The selected configuration was 4 µL of serum and 8 µL of 60 mM AChCl containing 5% (v/v) glycerol. Commercial serum-only controls without added substrate shifted the indicator from yellow to green, showing a sample-related contribution to the basal indicator color that may influence the final RGB signal. In a separate exploratory comparison using BChCl, blue-channel intensity was not significantly correlated with pre-treatment reference cholinesterase activity in the six human sera. These results provide a working configuration for further microdevice development and highlight the need to account for sample background.
Förderung
- Chilean National Agency for Research and Development
Zitieren
APA
Zúñiga-Hernández, J., Vielma, F. H., Berrocal-Navarrete, F., Marin-Sanhueza, P., Romero, P., García-Huidobro, J., & Zambra, C. E. (2026). Systematic Evaluation of a Two-Layer LF1/pH-Indicator Paper Assay for Serum Cholinesterase: Influence of Assay Conditions and Sample Background. Biosensors, 16(11), 628. https://doi.org/10.3390/bios16110628
Vancouver
Zúñiga-Hernández J, Vielma FH, Berrocal-Navarrete F, Marin-Sanhueza P, Romero P, García-Huidobro J, et al. Systematic Evaluation of a Two-Layer LF1/pH-Indicator Paper Assay for Serum Cholinesterase: Influence of Assay Conditions and Sample Background. Biosensors. 2026;16(11):628. doi:10.3390/bios16110628
BibTeX
@article{ZigaHernndez2026,
author = {Zúñiga-Hernández, Jessica and Vielma, Francisca Herrera and Berrocal-Navarrete, Fernanda and Marin-Sanhueza, Paz and Romero, Paula and García-Huidobro, Jenaro and Zambra, Carlos E.},
title = {Systematic Evaluation of a Two-Layer LF1/pH-Indicator Paper Assay for Serum Cholinesterase: Influence of Assay Conditions and Sample Background},
journal = {Biosensors},
year = {2026},
volume = {16},
number = {11},
pages = {628},
doi = {10.3390/bios16110628}
}
EUVIMED