EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Keyhole-Shaped Microwave Resonator for Hematocrit Sensing Toward Dengue Monitoring

Suhail Asghar Qureshi, Zuhairiah Zainal Abidin, Gameel Saleh

Biosensors · 29.10.2026 · 16 (11) · 614

DOI: 10.3390/bios16110614 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 29.10.2026. Verfasst von Suhail Asghar Qureshi und 2 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Saudi National Institute of Health.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and continuous monitoring of blood hematocrit (HCT) levels is critical for detecting hemoconcentration and plasma leakage associated with dengue virus progression. This paper presents a label-free, metamaterial-based microwave sensor designed to detect dielectric variations corresponding to changes in HCT. The proposed structural design utilizes a keyhole-shaped resonator. The sensor’s transmission coefficients (S21) were numerically evaluated using simulated dielectric properties representing an extended modelled HCT range of 0% to 80%. The simulated analysis demonstrates a systematic response, linear in resonance frequency (R2 = 0.996) and curved in magnitude (R2 = 0.812), achieving a resonance shift sensitivity of 4.5 MHz/%HCT and a magnitude sensitivity of 0.0599 dB/%HCT. Based on these simulations, a 20% relative rise from a patient’s baseline HCT (assuming = 50%) corresponds to a 45 MHz resonance shift and a −0.599 dB magnitude deviation. As an initial proof of concept, the prototype was tested with alcohol–water mixtures. Over 0–40% alcohol the resonance moved to lower frequencies, whereas above 60%, it reversed. This compact microwave sensor is a candidate framework for point-of-care HCT monitoring, subject to validation on blood.

Förderung

  • Saudi National Institute of Health

Zitieren

APA

Qureshi, S. A., Abidin, Z. Z., & Saleh, G. (2026). A Keyhole-Shaped Microwave Resonator for Hematocrit Sensing Toward Dengue Monitoring. Biosensors, 16(11), 614. https://doi.org/10.3390/bios16110614

Vancouver

Qureshi SA, Abidin ZZ, Saleh G. A Keyhole-Shaped Microwave Resonator for Hematocrit Sensing Toward Dengue Monitoring. Biosensors. 2026;16(11):614. doi:10.3390/bios16110614

BibTeX
@article{Qureshi2026,
  author = {Qureshi, Suhail Asghar and Abidin, Zuhairiah Zainal and Saleh, Gameel},
  title = {A Keyhole-Shaped Microwave Resonator for Hematocrit Sensing Toward Dengue Monitoring},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {614},
  doi = {10.3390/bios16110614}
}
Kostenlos starten →